• Fuse protection: -F1:FF 250mA H 600V, 10KA
• Power: 9V battery, NEDA 1604 or 6F22
• Display: LCD, 1999 counts, updates 2-3/sec.
• Measuring method: Dual-slope integration A/D converter
• Overrange Indication: Only figure "1" on the display
• Polarity indication: "-" displayed for negative polarity
• Operating Environment: 0 to 40ºC
• Storage temperature: -10ºC to 50ºC.
• Low battery indication: " " appears on the display
• Size: 144 mm × 74 mm × 40 mm
• Weight: Approx.(no rubber case): 160g.
6.2 DC Voltage
Range
Resolution
200mV
2V
20V
200V
600V
Overload Protection: 250V rms. For 200mV range and 600V dc or
rms. ac for other ranges
6.3 DC Current
Range
Resolution
20μA
200μA
2mA
20mA
200mA
10A
Overload Protection: F 200mA/250V fuse. (10A range unfused)
-F2:FF 10A H 600V, 10KA
100μV
1mV
10mV
100mV
1V
0,01μA
0,1μA
1μA
10μA
100μA
10mA
Accuracy
±0,5% of reading, ± 3 digits
±0,5% of reading, ± 5 digits
Accuracy
±1% of reading, ± 3 digits
±1% of reading, ± 5 digits
±1,5% of reading, ± 5 digits
±3% of reading, ± 10 digits
12
Digital multimeter