Replacement Of Air Purifying Filters; When Not Using The Air Conditioner For A; Pre-Season Inspection - Panasonic CS-V28BKP5 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24

Replacement of air purifying filters

Remove the air filters.
1
Air filter
<Note>
I Solar Refreshing Deodorizing Filter
• Used to remove unpleasant odour and deodorize the air in the room.
• Reusable.
• Vacuum, place under direct sunlight for 6 hours and fit it back in place.
(Recommended : every 6 months)
I Catechin Air Purifying Filter
• The filter is coated with catechin to prevent growth of bacteria and viruses.
• Reusable.
• Vacuum and fit it back in place
(Recommended : every 6 months)
When not using the air conditioner for a long period
1
Operate the air condi-
tioner for 2 to 3 hours.
I Type of operation: Fan.
In order to dry out the
internal mechanisms

Pre-season inspection

I Operate for 15
minutes.
If the difference in temperature
between the air outlet vent and
air intake vent is 8°C or more
when cooling, the unit is
normal.
Is cool air
coming out?
2
Remove the air purify-
ing filters.
Solar Refreshing
Catechin Air
Deodorizing Filter
Purifying Filter
2
For air conditioners with
a power plug, stop opera-
tion by remote control and
pull out the power plug.
Note: If the unit is not off by
remote control, the unit
will operate when you
plug in (because
of Auto-restart
Control is provided).
I Are the air outlet
vents and air intake
vents obstructed?
If they are, cooling
performance will drop and
cause problems.
3
Remove the filters
from the filter frame.
! Caution
Be careful not to
hurt your hands on
metal parts.
Filters
I Recommended to change these filters every 3 years.
Do not reuse damaged filters.
Consult the nearest authorized dealer to purchase a new filter.
Catechin Air Purifying Filter No.: CZ-SF71P
Solar Refreshing Deodorizing Filter No.: CZ-SFD71P
If you operate the air conditioner with dirty filters:-
– Air is not purified
– Cooling capacity decreases
– Foul odour is emitted
3
Remove the batteries
from the remote control.
(The earlier the better)
I Is the drain hose
cracked or crushed?
If it is, leaks will
result.
I
Are the remote
control batteries in
good condition?
If display is faint or
no display is visible,
the batteries should
be replaced.
18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cu-v28bkp5

Table des Matières