Typical Installation - GE GXWH40L Instructions D'installation

Masquer les pouces Voir aussi pour GXWH40L:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Performance Data
This housing has been tested according to NSF/ANSI 42
for the reduction of the substances listed below. The
concentration of the indicated substances in water
entering the housing was reduced to a concentration
less than or equal to the permissible limit for water
leaving the housing, as specified in NSF/ANSI 42.
Filter Cartridge Replacement
You should change your filter when the water flow is noticeably reduced or at least every 3 months.
Turn off water to filter. Rotate the control handle to the
1
BYPASS or OFF position (see Valve Operations section).
Press the red pressure release button to release pressure.
2
Unscrew the filter canister and discard used filter. Wash the
3
filter canister with mild soap and water. Do not use harsh
cleaners or hot water.
Inspect the filter canister O-ring. Make sure it is lightly
4
lubricated with clean food grade silicone grease (silicone
grease is available through GE Parts and Service:
1.800.626.2002, part number WS60X10005). Be sure the
o-ring is seated in the groove. It is recommended that you
replace the O-ring if it is damaged.
Place a new filter cartridge into the canister, making sure it is
5
centered and completely seated on the bottom seal.
Reinstall the filter canister to the unit. Use the canister
6
wrench to tighten the canister. DO NOT OVERTIGHTEN.
Control Handle
OFF
Shuts off water.
Installation Overview
NOTE: Be sure to allow a minimum space
" –2 " under the filter for removing
of 1
1
2
the sump to change the cartridge.
CARTRIDGE SPECIFICATIONS
FILTER
For filtered water. Directs water flow
through filter.
STEP-BY-STEP INSTALLATION INSTRUCTIONS
Mounting
bracket
Ferrule
Hex nut
Recommended
shut-off valve
FXHTC Cartridge
Influent Challenge
Substance
Concentration
Standard 42
2.0 mg/L ±10%
Chlorine
Test Conditions
Flow Rate: 3 gpm (11.4 Lpm)
pH: 7.5±1
Inlet Pressure: 60 PSI (4.1 bar)
Temperature: 68°F ± 5°F (19.8°C ± 2.5°C)
Testing was performed under standard laboratory conditions; actual performance may vary.
Slowly rotate the control handle to the FILTER position.
7
Press the red pressure release button to remove trapped air.
8
After installation, open any downstream faucet and flush the
9
cartridge for 10 minutes, wait one hour, then flush again for
10 minutes before using the water.
Control handle
Turn canister wrench
clockwise to remove
Canister
Permits flow of water to the house without flowing through the filter.
Use this position for filter changes or if filtered water is not desired
Ferrule
Fitting
Fitting
"–2"
1
1
2
2
Reduction
Requirements
≥50%
Operating Requirements
Pressure: 30–100 PSI (2.1–6.9 bar)
Turbidity: 5 NTU Max.
Temperature: 40°F–100°F (4.4°C–37.7°C)
Capacity: 5,000 gallons (18,927L) or 3 months
Remote timer
Filter
cartridge
Turn
clockwise
to remove
canister
BYPASS
Hex nut
Recommended
shut-off valve

Typical installation

Average
Reduction
93.1%
Red pressure
release button
Head
O-ring seal
Filter canister
Turn
counterclockwise
to tighten
.

Publicité

Table des Matières
loading

Table des Matières