Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Household Water Filtration Housing* — GXWH04F and GXWH20F
Check with your state and local public works department
for plumbing and sanitation codes. You must follow these
guidelines as you install the Household Water Filtration
Housing. Using a qualified installer is recommended.
Be sure the water supply conforms with the Specifications
Guidelines . If the water supply conditions are unknown,
contact your municipal water company.
This Household Water Filtration Housing must be properly installed and located in accordance with the Installation Instructions before it is used.
Check with your local public works department for plumbing codes.
You must follow their guides as you install the Household Water
Filtration Housing.
Use the Household Water Filtration Housing on a potable, safe-to-
drink, home COLD water supply only. The filter cartridge will not
purify water or make unsafe water safe to drink. DO NOT use on
HOT water (100˚F max).
Protect the Household Water Filtration Housing and piping from
freezing. Water freezing in the housing will damage it.
Your Household Water Filtration Housing will withstand up to 125 psi
water pressure. If your house water supply pressure is higher than
100 psi during the day (it may reach higher levels at night), install
a pressure-reducing valve before the housing is installed.
REQUIRED TOOLS AND ACCESSORIES
FOR INSTALLATION
" and 1
2 wrenches: 1
1
1
8
4
Pipe cutter
Ruler or tape measure
Cordless drill and a 3/16" drill bit
(optional)
File
Emery paper
Screwdriver
For GXWH04F model, additional
installation parts may be required:
" compression adapters with
• (2)
3
4
brass ferrule and nut for installation
on copper plumbing—Installation Kit
available:
The FXUSC (Rev. 2) filter is tested and
certified by NSF International against
NSF/ANSI Standard 42 for materials
requirement only.
COMPONENT
GE Smar tWater
INSTALLATION INSTRUCTIONS
SAFETY PRECAUTIONS
PROPER INSTALLATION
— Retail Part (WHKIT)
— GE Parts (WS35X10023)
"
• UL-approved grounding clamps and
6-gauge copper grounding wire—
Installation Kit available:
— Retail Part (WHKIT)
— GE Parts (WS35X10023)
• Teflon Tape
Optional accessories are available (Visa,
MasterCard or Discover cards accepted) by
visiting our Website at ge.com or from Parts and
Accessories 800.626.2002 (U.S.) or 800.663.6060
(Canada).
If unit is to be installed on plastic,
PVC or galvanized plumbing, separate
hardware must be purchased.
This GXWH04F is tested and certified by
NSF International against NSF/ANSI
Standard 42 for materials and structural
integrity requirements only.
184D1060P002
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
WARNING:
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system.
It is highly recommended that a water shut-off valve be placed
directly upstream of your household filter.
Do not install on HOT WATER . The temperature of the water
supply to the Household Filtration Housing must be between the
minimum of 40°F and the maximum of 100°F. See the
Specification Guidelines .
Do not install the Household Water Filtration Housing using
copper solder fittings. The heat from the soldering process
will damage the unit. If making a soldered copper installation,
do all sweat soldering before connecting pipes to the housing.
Torch heat will damage plastic parts.
WARNING:
Discard all unused parts and packaging material
after installation. Small parts remaining after installation could
be a choke hazard.
Do not install filter in an outside location or anywhere it will be
exposed to sunlight.
COMPONENT
49-50202-1
01-08 JR
ge.com
1
CONTENTS INCLUDED WITH PRODUCT
Filter housing and head
Product literature
Sediment filter FXUSC (Rev. 2)
(for GXWH20F only)
" brass compression fittings with
(2)
3
4
nut and ferrule (for GXWH20F only)
Teflon tape (for GXWH20F only)
Canister wrench
Grounding clamps and wire (for
GXWH20F only)
Mounting bracket with (2) screws
Timer and batteries
The GXWH20F system using FXUSC (Rev. 2)
filter is tested and certified by NSF
International against NSF/ANSI Standard 42
for reduction of particulate Class V.

Publicité

Table des Matières
loading

Sommaire des Matières pour GE SmartWater GXWH04F

  • Page 1 Grounding clamps and wire (for MasterCard or Discover cards accepted) by For GXWH04F model, additional GXWH20F only) visiting our Website at ge.com or from Parts and installation parts may be required: Mounting bracket with (2) screws Accessories 800.626.2002 (U.S.) or 800.663.6060 ″...
  • Page 2 GXWH20F Red pressure Timer lightly lubricated with clean food grade silicone release button Timer grease (silicone grease is available through GE Parts and Service: 1.800.626.2002, part number Head WS60S10005). Be sure the O-ring is seated in the Head Control Red pressure groove.
  • Page 3 STEP-BY-STEP INSTALLATION INSTRUCTIONS Installation Overview GXWH04F GXWH20F ″ NOTE: Be sure to allow a minimum space of 1 ⁄ under the filter for removing the sump, to change Recommended Recommended the cartridge. shut-off valve shut-off valve Recommended shut-off valve Recommended shut-off valve Select Location It is recommended that a shut-off valve be placed on both sides...
  • Page 4 For GXWH04F, wire and clamps may be purchased separately Clamp from your local hardware store, or are available by visiting our Website at ge.com, or from Parts and Accessories by calling 800.626.2002 (U.S.)or 800.663.6060 (Canada)—order part number WHKIT. Final Check Install filter, if not already done.
  • Page 5: Parts List

    To know what your legal rights are, consult your local or state consumer affairs office or your state’s — One (1) year. Attorney General. Contact us at ge.com, or call toll-free at 800.952.5039 in the U.S., or 866.777.7627 in Canada.
  • Page 6: Mesures De Sécurité

    Visa, Mastercard ou Discover acceptées) en visitant Clé pour corps de filtre Pour le modèle GXWH04F, il peut être notre site Web à ge.com ou en vous adressant à notre nécessaire d’avoir des accessoires Brides et conducteur de liaison à la terre service des Pièces et Accessoires au 800.626.2002...
  • Page 7: La Cartouche De Filtration

    (vous trouverez la graisse de silicone au GXWH04F GXWH20F Bouton rouge de Minuterie service de pièces et d’entretien GE, en téléphonant dépressurisation Minuterie au 1.800.626.2002, numéro de pièce WS60S10005). Assurez-vous que le joint torique repose bien dans Tête le sillon.
  • Page 8: Étapes De L'installation

    ÉTAPES DE L’INSTALLATION Illustration de l’installation GXWH04F GXWH20F NOTE : Veiller à ce qu’il y ait un espace libre d’au moins 1 ⁄ po sous le filtre pour l’extraction du corps Robinet d’arrêt– Robinet d’arrêt– de filtre lors du changement de la cartouche. recommandé...
  • Page 9: Étapes De L'installation (Suite)

    N’utilisez pas d’attaches en zinc sur le cuivre. Pour le modèle GXWH04F, il est possible d’acquérir le fil et les attaches séparément chez votre visitant notre site Web à ge.com ou en vous adressant à notre Bride service des Pièces et Accessoires au 800.626.2002 (aux Etats-Unis) ou 800.361.3869 (En Canada).
  • Page 10: Liste Des Pièces

    • Quelle est la durée de la garantie après l’achat? votre État. — Un an. Contactez nous sur ge.com, ou appelez le numéro sans frais 800.952.5039 aux États-Unis. Au Canada, contactez nous sur www.electromenagersge.ca, ou appelez le numéro sans frais 866.777.7627.
  • Page 11 NOTES • NOTAS...
  • Page 12: Precauciones De Seguridad

    Destornillador Visa, MasterCard o Discover) visitando nuestro solamente Para el modelo GXWH04F, es posible que se Website a ge.com o en el Departamento de Partes Llave para el receptáculo necesite partes adicionales para completar la y Accesorios en el 800.625.2002.
  • Page 13 Cronómetro usar en alimentos (la grasa de silicona está disponible a reducir la presión Cronómetro través del departamento de Partes y Servicio de GE llamando al 1.800.626.2002, número de parte Cabeza WS60S10005). Cerciórese de que el aro tórico está Botón rojo para Manija en la ranura.
  • Page 14 INSTRUCCIONES DE INSTALACION PASO A PASO Sumario de la instalación GXWH20F GXWH04F NOTA: Asegúrese de dejar un espacio mínimo de ″ debajo del filtro para sacar el esceptáculo, ⁄ Válvula de cierre Válvula de cierre para cambiar el cartucho. recomendada recomendada Válvula de cierre Válvula de cierre...
  • Page 15 Website a ge.com o en nuestro Departamento de Partes y Accesorios al 800.626.2002— ordene el número de la parte WHKIT.
  • Page 16: Lista De Partes

    • ¿Por cuánto tiempo después de la compra? local o la oficina del Attorney General en su localidad. — Un año. Póngase en contacto con nosotros en ge.com, o llame sin cargo al 800.952.5039, o 866.777.7627 en Canada. Printed in China Imprimé...

Ce manuel est également adapté pour:

Smartwater gxwh20f

Table des Matières