11 Disassembly
11 Disassembly
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout the entire duration of maintenance, servicing,
assembly, disassembly and repair work:
• Switch off the power source.
• Disconnect all electrical connections.
NOTICE
• Disassembly may only be carried out by qualified personnel (in Germany see TRBS 1203).
• Please also consult the operating instructions for the welding components and welding torch.
• Observe the information provided in the following section:
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
12 Disposal
When disposing of the system, local regulations, laws, provisions, standards and guidelines must be
observed. Observe the regulations on the disposal of electronic scrap and dispose of it at your local waste
disposal site (e.g. recycling centre).
To correctly dispose of the product, it first must be disassembled. Please take note of the following
information:
11 Disassembly on page EN-18
BTC coolants:
The coolant must not be disposed of with normal household waste. Do not allow it to enter the sewage
system. Please take note of the following information in the safety data sheet:
Section 13 Disposal instructions
• 14 06 03*: other solvents and solvent mixtures
• 15 01 10*: Packaging that contains residues of dangerous materials or has been soiled by dangerous
materials
• 15 01 02: Plastic packaging
Contaminated packaging:
Recommendation: disposal in accordance with official regulations.
Recommended cleaning agents: water, if necessary with added cleansing agents.
EN - 18
DANGER
8 Putting out of operation on page EN-15.
DANGER
CR1000/CR1250