6 Putting into operation
6.1 Transport and installation

Risk of injury

Physical injury due to falling devices and add-on components.
• Avoid abrupt lifting and setting down.
• Do not lift the components over persons or other devices.
• Transport the components in an upright position only and with an empty coolant container to prevent
• Wear your personal protective equipment: safety shoes with steel toe caps, protective work gloves,
• Send bystanders out of the danger zone.
• Note the weight of the individual components.
Risk of toppling
Physical injury or damage to components due to improper assembly.
• Disconnect the supply lines.
• Place the components on a suitable base (flat, solid, dry) on which they will not topple over.
• Note the max. tilt angle of 10°.
NOTICE
• Ensure free access to the operating components and connections.
• Install the cooling unit with a circumferential clearance of 50 cm to ensure optimum cooling air
• Prevent dust and other foreign substances from entering the system's cooling air stream.
• Protect the components against rain and direct sunlight.
• Only use the device in dry, clean and well-ventilated rooms.
6.2 Connecting the cooling unit
6.2.1 Fuse protection for the cooling unit
NOTICE
• The units are protected by a fuse/fuses in different ways, depending on the version.:
EN - 12
CAUTION
coolant leakage.
safety helmet, ear protectors.
 3 Product description on page EN-5
CAUTION
circulation.
CR1000/1250 with 115 V is protected by a 5A fuse..
CR1000/1250 with 230 V is protected by a 3A fuse.
CR1000/1250 with 400 V is protected by three 1A fuses.
CR1000/CR1250