Inputs and Outputs
Table 1 Inputs and Outputs
Property
Analog output
Power supply input
Each current loop output
requires its own power supply.
Service port connector
Cable feed throughs
Screw terminal wire size
1)
Available calculated parameters for HMD62 include T
2)
Vaisala Insight software for Windows available at www.vaisala.com/insight.
CAUTION!
documentation. Improper modification may lead to safety hazards, equipment
damage, failure to perform according to specification, or decreased equipment
lifetime.
12
Do not modify the unit or use it in ways not described in the
Specification
HMD62:
1)
• 1 x RH output
4 ... 20 mA current, loop
powered
• 1 x T output 4 ... 20 mA current, loop powered
TMD62:
• 1 x T output 4 ... 20 mA current, loop powered
10 ... 35 VDC (RL = 0 Ω)
20 ... 35 VDC (RL = 600 Ω)
M8 4-pin male connector for MI70 hand-held
indicator (requires cable accessory 219980SP)
or Vaisala Insight PC software cable connection
(requires USB cable accessory 219690)
• M16 x 1.5 inlet, options available from Vaisala:
• Cable Gland M16 x 1.5 (Vaisala order code:
254280SP). This is the default option
delivered with HMD60.
• Conduit Fitting M16x1.5, ½"NPT (Vaisala
order code: 210675SP)
• Alternative M20 x 1.5 inlet
2
0.5 ... 1.5 mm
, T
, A, X, T
, and H.
d
df
w
2)
M212049EN-B