Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and/or property damage! Retain instructions for future reference.
Operating Instructions
Description
This pump is intended for use in domestic
sump or effluent lift stations. It is suitable
for pumping effluent, wastewater, ground
water and other nonexplosive, noncorrosive
liquids with up to 3/4" solids. The pump
includes a wide angle float switch that turns
the pump on and off as the fluid level rises
and falls.
Effluent pump will
not pump raw
sewage or any substance exceeding
3/4" size.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY and
to PREVENT EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially
hazardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
potentially
hazardous situation which, if not avoided,
MAY result in minor or moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
Specifications
Power supply requirements.............115V, 60 hz
Circuit requirements ........................15 amps (min)
Motor duty .......................................Intermittent
Motor ................................................115V, 1 Phase, 1725 RPM
Horsepower .....................................1/3
Motor full load.................................5 amps
Liquid temperature range...............40°F to 120°F
Max. operating position ..................45
Dimensions .......................................13-1/2" x 11"
Intake ................................................3/4"
Discharge ..........................................2" NPT female
Cut-in level (factory set) ..................14-1/2"
Cut-out level (factory set)................5-3/4"
Differential .......................................8-3/4"
Switch................................................90
Power cord........................................18 gauge 3 conductor w/plug
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2004
All manuals and user guides at all-guides.com
General Safety Information
1. Know the pump application, limitations,
and po ten tial hazards.
Do not use to pump
flammable or explosive fluids
such as gasoline, fuel oil,
kerosene, etc. Do not use in
flammable and/or explosive atmospheres.
Use pump only with liquids compatible
with pump component materials. Failure
to follow this warning can result in
personal injury and/or property damage.
2. Make certain that the power source
(electric motor) conforms to the
requirements of the equipment.
Disconnect power before
servicing. If the power dis -
con nect is out of sight, lock
in the open po si tion and
tag it to prevent unexpected
application of power. Failure to do so
could result in fatal electrical shock!
3. Release all pressure within the system
before ser vic ing any component.
4. Drain all liquids from the system before
servicing.
5. Secure the discharge line before starting
the pump. An unsecured discharge line
will whip, possibly causing personal
injury and/or property damage.
from vertical
o
o
wide angle mechanical
tether switch
For parts, product & service information
visit www.waynepumps.com
Effluent
Pump
Construction
Motor body material .......................Cast Iron
Motor housing .................................Cast Iron
Volute ...............................................Cast Iron
Impeller.............................................Glass reinforced PBT
Performance
GALLONS PER HOUR AT TOTAL HEAD IN FEET
Model
10
EFL30
2900
Model EFL30
6. Check hoses for weak and worn
condition before each use, making
certain that all connections are secure.
7. Periodically inspect the pump and
system com po nents. Perform routine
maintenance as required (See
Maintenance Section).
8. Provide a means of pressure relief for
pumps whose discharge line can be shut-
off or obstructed.
9. Personal Safety:
a. Wear safety glasses at all times when
working with pumps.
b. Keep work area clean, uncluttered
and properly lighted; replace all
unused tools and equipment.
c. Keep visitors a safe distance from the
work area. Make workshop child-
proof with pad locks, master switch es,
and by re mov ing starter keys.
10. When wiring an elec tri cal ly driven pump
such as this, fol low all electrical and safety
codes, as well as the most recent National
Electrical Code (NEC) and the Oc cu pa tion -
al Safety and Health Act (OSHA).
Risk of electric shock!
Never connect the green
(or green and yellow) wire
to a live terminal!
11. This equipment is only for use on 120
volt (single-phase) and is equipped with
15
20
2280
1380
331400-001 9/04