Connection of relay outputs (RL1 / RL2)
The connection is made via a 3-point terminal block providing the "Common (C) / Rest (NC) / Work (NO)" interface.
If you use one of these relay outputs to control an AC or DC strike, wire a non-polarized 58V diode in parallel to the
dry contact between C and NO or C and NC depending on use (diode supplied).
Protection against electrostatic discharges
Connect the device to the ground using the terminal provided (Mounted on the fixing of the microphone).
Connection of inputs 3 to 6 (Inputs)
our digital inputs (IN3 / IN4 / IN5 / IN6) allow the connection of a dry contact (do not apply voltage). To be activated,
the input must be grounded (0V).
The contact can be deported up to 1Km.
12V or 24V power source for accessories (Out <100mA)
Function only available when the device is powered by PoE+ or an external power
supply to supply external accessories such as an output BP, a radar, a light in the limit of 24V / 50mA max or 12V /
100mA max
Connecting the external reader (External Reader)
The reader, digital code reader or reader equipped with a connected keyboard can be of type Wiegand (D0 & D1).
Compatible formats are Wiegand 26, 32, 34, 37, 44, 56 and 58 bit
Two open collector outputs allow to control the LED Red (LED R) and Green (LED V) of the reader or digital code
connected.
When the device is powered by PoE+ or an external power
within the limit of 5V / 100mA or 12V / 100mA (and up to 200mA if the power supply 12V accessories is not used). For
any reader with a higher consumption, provide an external power supply.
The connection is made by wire-to-wire connection, see the data sheet of the connected reader.
Connection of external access control system (External Access Control)
The device's built-in reader has an 8-pin connector for connection to the customer access control system. In this case
of use, the reader is no longer managed by the CASTEL device and must be powered by the external access control
system.
The maximum distance between the reader and the access control system is 100m max with 6/10 type cable.
Connect one end of the cable screen to ground.
The required power supply (+ VDC / 0V):
• Power supply 9 to 15VDC
• Consumption: 150mA / 12V
The interface is of type Wiegand (D0 & D1) 56 bits.
Two inputs to control the LED Red (LED R) and Green (LED V)
A "Buzzer" input is used to control the reader's buzzer
A "Tamper" output is used to signal the tearing off, do not connect because not available
Technical data sheet no. 604-0403E
Applicable from software version 1.5.0
www.castel.fr
supply, it provides a power
supply, it can power the external drive (+ Vdc / 0V)