Manual
BVS 15 ATEX E 035
No modifications or repairs may be carried
out on the explosionproof tube lights TL**tb.
Whenever work is done on the explosion-
proof tube lights TL**tb, the national safety
and accident prevention regulations and the
safety instructions given in this Manual (stat-
ed in italics as in this paragraph) must
always be observed.
2.
Conformity with Standards
The explosionproof tube lights TL**tb meet the
requirements of IEC 60079-0 and IEC 60079-31.
They have been developed, manufactured and
tested in accordance with state-of-the-art engi-
neering practice and ISO 9001:2015.
3.
Technical Data
3.1
Marking
3.1.1 Marking as per ATEX
II 2D
3.1.2 Marking according to IEC 60079-0
Ex tb IIIC T95°C Db
3.2
Certification
3.2.1 EU-type examination certificate
BVS 15 ATEX E 035
3.2.2 IECEx Scheme
IECEx BVS 15.0029
3.3
Lamp enclosure ingress protection
Degree of protection IP 66
Edition August 2019
Copyright
thuba EHB Ltd., CH-4002 Basel
Switzerland