2. SAFETY
This section provides an overview of all the important safety aspects to ensure the protection of your staff
and the safe and trouble-free operation of the equipment. Further safety information relating to specifi c tasks
can be found in the sections on the individual life cycle phases.
2.1. INTENDED USE
The R200, R300 and R500 line regulator is only usable for the defi ned standard gases and pressures
observing the given temperature range. The nominal fl ow is 20 m3/h (Air).
Intended use also includes compliance with all the information in these instructions and compliance with
reparation, maintenance working, type label and data sheets.
Any use other than, or above and beyond, the intended use constitutes improper use.
WARNING!
•
Danger from improper use!
•
Improper use of the system can lead to dangerous situations.
•
Never use the line regulator with liquid fl uids.
2.1.1. STRUCTURAL CHANGES AT THE LINE REGULATOR
Without written approval of manufacturer no extensions, additions or alternations are allowed on the line
regulator.
Line regulator which are not in perfect condition have to be changed immediately.
Cleaning of line regulator and disposal of residues
Used line regulator which are ready for reparation has to be purged with an inert gas (nitrogen) before.
Noise Generation
In some cases when specifi c infl uence quantities collaborate together, e.g. fl ow and pressure range can
cause noise generation or the gas itself. If this happens please contact manufacturer.
2.2. FUNDAMENTAL RISKS
The following section addresses the residual risks that may arise, even if the system is used properly.
Observance of the safety information included below and in other sections of these instructions is mandatory
in order to reduce the risk of injury and property damage and to avoid dangerous situations.
DANGER!
•
Gases can be life threatening!
•
Gases can supersede the oxygen in air. This can result in death by asphyxiation. Oxygen produces a
strongly oxidizing eff ect.
THEREFORE:
•
Suffi cient ventilation is absolutely essential.
•
Installation only through certifi ed company.
•
Observe ATEX directive.
ATTENTION!
•
Risk of injury from environment!
There can be malfunctions on component due to condensation and/ or icing.
THEREFORE:
•
Observe suitable temperatures.
•
Protect component from liquids from outside
•
Protect component from dust from outside
•
Protect component from weather conditions
•
Grounding has to be mounted properly
7/298
EN