Setting up the 1-channel receiver RVQ504C1 / RVQ508C1 (fig. 5)
The receiver can be set-up using the dip-switches S1:
Timer setting
Timer-controlled
dip 1
Memo radio
dip 2
Relay On/Off
dip 3
dip 4
relay
max. 255 s
ON
enabled
ON
enabled
ON
enabled
ON
time count enabled
OFF
disabled
OFF
disabled
OFF
disabled
OFF
time count disabled
To set the relay activation time move Dip 4 to position 'ON'; press 'P1' (LED 'L1' will flash and the time count
will start); premere 'P1' again (LED 'L1' remains lit and the time count will end); move Dip 4 to position 'OFF'.
Fixed position output relays RVQ504C4 / RVQ508C4 (fig. 6)
The 4 output relays can be set via dip-switches (Dip1 = CHA - Dip2 = CHB - Dip3 = CHC - Dip4 = CHD) to
the following:
- Timer-controlled channel modules = corresponding dip-switch set to 'OFF'
- ON/OFF channel modules = corresponding dip-switch set to 'ON'
In the timer-controlled modules the activation time can be set by means of the trimmer T1 from 1 to 250 s.
Set Trimmer T1 to 0 sec. to enable the impulsive function.
To change the relay function mode (from timer controlled to ON/OFF and the other way round) the
receiver must be switched off and restarted.
Receiver code memory module M1
The codes are stored in a non-volatile EEPROM memory module.
The receiver is designed to manage up to 1000 users (1000 transmitters) with the possibility of memorising
and cancelling each individual user. For each transmitter it is possible to memorize a maximum of 4 functions.
The memorized codes are maintained in this module even in the absence of power for an unlimited period of time.
Bluetooth (only RVQ504C4 / RVQ508C4)
By inserting the module into the connector BT (fig. 6) and downloading the application CRD ONE it is possible
to command the relays via Bluetooth. Tha App CRD ONE allows you to activate the receiver outputs (relays
CHA - CHB - CHC - CHD) and to monitor the status of the inputs (open/close).