Important Installation Instructions - SSS Siedle KR 614-1/1 Information Produit

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
English
Application
Combination frame for modernising
an existing Vario 511 door station to
the current Vario 611 series, made
of sectional extruded aluminium
powder-coated or painted.
Letterboxes and flush-mount hous-
ings that are already plastered in can
continue to be used.
The fixing material for installing a
letterbox module and mounting
frame is included.
Because of the increased capacity
of the letterbox, the frame stands
approx. 50 mm proud of the wall.
A solution is available on request for
transverse mounting.
Making good, wall connection and
sealing work must be professionally
performed by the client.
Because of the increased capacity of
the letterbox, the frame stands appr.
50 mm proud of the wall.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
Important installation instruc-
tions
• The combination frame
KR 614-1/1-... only fits on the
existing flush-mount housing TL/
BKGU 514-...
• The housing must be sealed
against the wall by the customer
using all-round acrylic grouting or a
suitable sealant.
• Depending on the mounting situ-
ation, the service of a decorator or
plasterer may be required.
Scope of supply
• Combination frame KR 614-1/1-...
• 2 sealing profile strips
• 8 screws M10 x 40
• 4 tapping screws 4 x 70 mm
• 2 adapter plates
• Vario 511 key
• This product information
6
Mounting
Before starting renovation work,
disconnect the line rectifier of the
intercom from the mains.
1 Unlock the mounting frame with
the silver Vario 511 key and open
up. Before disconnecting the termi-
nals, inscribe then with the terminal
names. Disconnect all connected
cores, loosen the 4 existing slotted
screws of the mounting frame. Pull
the mounting frame off towards the
front. Release the 4 Phillips screws
of the letterbox module BKM 514-...
Pull the letterbox off towards the
front.
2 Expose the peripheral sheet metal
rim of the existing flush-mount
housing and clean off any plaster
residues/dirt. The wall around the
sheet metal rim must be flush
against the flush-mount housing
over a width of 5 mm.
3 Glue the seal onto the suitable
edge of the flush-mount housing.
4 Insert the small adapter plate into
the flush mount housing. Hang the
large adapter plate into the flush
mount housing.
5 Press the combination frame
against the wall and screw to the
adapter plate.
6 Remove the combination frame
from the module packaging. Centre
the combination terminals turned
around 45° anticlockwise onto the
relevant receptacles in the upper
adapter plate. Lock the combination
terminals into place clockwise with
a 45° turn. The terminal designa-
tion must be capable of being read
vertically. Install the new modules in
accordance with the existing circuit
diagram.
7 Insert the mounting frame in such
a way that the sealing film is located
at the upper edge of the mounting
frame.
8 At the letterbox module, exchange
the 4 pre-mounted tapping screws
of the mounting claws for the longer
tapping screws (4 x 70).
9 Insert the letterbox module and
tighten against the combination
frame with the 4 screws using mod-
erate force.
10 Insert the Vario modules.
11 Following function testing, seal
the combination frame to the wall
using acrylic or a suitable sealing
material.
Specifications
Dimensions (mm) W x H x D:
431 x 542 x 50