Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

VII - TECHNICIAN MENU
Access to the technician menu is via the two push buttons [SELECT] and [+] located on the
back of the clock. The [SELECT] button is above the [+] button.
Proceed in two stages.
1. Press the [SELECT] button, and while holding it down, press [+] for more than 3 seconds to
go initially to Configuration menu.
2. Press the [SELECT] button, and while holding it down, press [+] for more
than 7 seconds to go to Technician menu. The programme version for the
clock is displayed.
3. Press the [SELECT] button to display the menu for the type of
synchronisation. The [+] button enables you to choose between Ind, NTP
and NTPi.
Ind : autonomous mode (deactivation of NTP synchronisation
card).
NTP : activation of NTP synchronisation card. After 24 hours
without synchronisation, the clock stops.
NTPi : activation of NTP synchronisation card. After 24 hours
without synchronisation, the clock continues to function
autonomously.
4. Press [SELECT], according to the clock's option and the previous selection :
Ind : the programme of the clock go directly to the step "Test
display".
NTP or NTPi : The Multicast address configuration menu offers
you two choices depending on the server (49 or 54),
239.192.*54.*xx (*54 *: default value); use the [+] key to select the value.
Press [SELECT] to validate; you then have the end of the
Multicast address to enter in accordance with the server.
Value from 1 to 15; use the [+] key to select the value.
Example of programmable address: 239.192.54*.01 *(*01 *:
default value).
Caution: the address configured in the clock must be the same as that entered in the
Multicast NTP server.