Kohler K-6356 Guide D'installation page 8

Masquer les pouces Voir aussi pour K-6356:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Bonnet
Mounting Nut
7. Optional Temperature Limiting Adjustment
NOTE: Before adjusting the water temperature, ensure the handle is
turned all the way to the left. This is the maximum hot position.
Loosen the setscrew.
Remove the handle and bonnet.
Turn on the water to the maximum temperature by pushing the
valve stem up and turning it clockwise.
Mark the current position of the temperature stop tab (top edge)
on the mounting nut with a marker or pencil.
Lift the indexer and top disc just enough to clear the valve
splines and to allow rotation.
NOTE: Each spline notch is an average 9.5°F (5.3°C) change in
temperature.
Turn the indexer, top disc, and valve stem counterclockwise until
the desired temperature is achieved.
Reinstall the indexer and top disc to the valve, making sure the
top disc is snapped fully into the indexer.
Turn off the water by pulling the valve stem down.
Reinstall the bonnet and handle.
Tighten the setscrew.
1025491-2-C
Handle
Setscrew
Valve Stem
Stop Tab
Top Disc
Indexer
Splines
8
Kohler Co.

Publicité

Table des Matières
loading

Table des Matières