Ivalo Finiré 3" LED Downlights
Installation Instructions
Troubleshooting
Symptoms
The light is flickering,
flashing, dropping out, or
does not turn on.
LED exhibits a flash or
steppy dimming on first use.
LED does not dim.
Trim does not fit.
If a Lutron system is installed on-site and assistance is needed with programming or
performance issues, please contact Lutron Lighting technical support at 1.844.LUTRON1
(1.844.588.7661) or lightingsupport@lutron.com

FCC Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired operation. Modifications not expressly approved by Lutron Electronics
Co., Inc. could void the user's authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
CAN ICES-005 (B) / NMB-005 (B)
Solution(s)
• Check all fixture wires and connections to ensure that they are properly connected.
• Verify that controls and controllers (drivers) are connected properly.
• Verify that a compatible control is being used to control the controller (driver). For a list of
compatible controls and control ratings, visit www.lutron.com/finire
• Ensure that 120 / 277 V~ power is present and properly connected to the LED controller
(driver). Note: F1 model (2-wire) is 120 V~ only.
• Adjust low-end trim on the control.
• Verify that ambient temperature is within the specified range.
• Non-IC fixtures are intended for free air applications. Do not confine Non-IC fixtures with
insulation or building materials.
• Drivers will "learn" the LED load on first startup. This is a one-time event for a particular
controller (driver)/LED combination. Running the load at full output for 20 seconds will
complete "learning."
• Verify that the controller (driver) wiring is wired properly.
• Verify that an adjustable trim is being used with an adjustable housing.
If using a downlight trim with an Adjustable fixture, verify that the tilt is 20° or less.
• Trimless fixtures: Ensure that the inside of mud ring is free of excess plaster.
• Trimmed fixtures: Ensure ceiling material thickness matches trim specification. Thick ceiling
trim brackets are required for ceiling material greater than 0.625 in (16 mm).