Ivalo Finiré 3" LED Downlights
Installation Instructions
Important Notes
• IC fixtures must be used for installations containing insulating materials and must be mounted away from heat producing elements (e.g., HVAC ducts, hot water
pipes, radiant heat floors, ovens). Non-IC fixtures cannot be used in these types of applications.
• Non-IC fixtures are intended for free air applications. Do not confine Non-IC fixtures with insulation or building materials.
• Install and wire in accordance with national and local electrical codes, by a qualified professional familiar with the construction and operation of luminaire
electrical systems and the hazards involved.
• IC fixtures are rated for direct application of spray foam with less than R-21 insulative value or 3 in (76.2 mm) of closed cell spray foam. 95 °F (35 °C) maximum
operating temperature.
• The mud ring shipped with trimless fixtures must be installed to ensure desirable ceiling aesthetic and to provide structural support.
• Hanger bars can be installed on either side of the fixture.
• Housings, modules, and trims are shipped in separate packages. Install modules and trims per housing labels (see Step 6a).
• Installation details with materials other than drywall or plaster, please see Application Note #564 at www.lutron.com.
• Sloped ceiling installation: Install housing with junction box at bottom of slope. Adjustable fixtures accommodate up to 40° slope (10/12 roof pitch).
Dimensions
IC Housing
1
Top View
16.1 in
(409 mm)
9.5 in
(241 mm)
Bottom View
2
4.8 in
(122 mm)
The plenum rated fixture has the same dimensions as the IC housing.
1
Round downlight fixture shown.
2
Fixture Installation
1. Turn off power.
WARNING: Electric Shock Hazard. Serious
Injury or Death may occur. Turn off power before
servicing or installing. Wire according to local
and national codes. This product should be
installed by a qualified electrician.
2. Install fixture using the hanger bar based on mounting method
(Figure 1). Hanger bars can be installed on either side of the fixture.
a. Insert hanger bars into hanger bar clamp.
b. Use hanger bar to secure to structure (notch allows for T-bar
installation). Secure wires (not included) to hanger bar (if required).
c. Hammer barb into stud or secure with mounting screws provided
by others.
d. Optional: Use set screws provided to lock hanger bars.
Notes: For T-bar installation details, please see Lutron Application Note #564.
Hanger bars cannot be locked on the junction box side of the housing.
3. Make power connections. See Circuit Diagrams for Dimming (Pg. 5).
Note: Do not trim wire length from LED controller (driver). Wire length is required
for controller (driver) accessibility after fixture is installed.
6.0 in
(152 mm)
18.9 in
(480 mm)
6.5 in
(165 mm)
2.1 in
(53.3 mm)
IMPORTANT INFORMATION
Please Read Before Installing
Non-IC Housing
Top View
10.9 in
(277 mm)
9.5 in
(241 mm)
Bottom View
2
4.8 in
(122 mm)
Figure 1
Joist
Clip
Leads and
ground
bundled in
Hanger
junction box.
bar clamp
Figure 2
Cardboard
housing insert
367-2578k
1 06.18.21
4.9 in
(124 mm)
13.6 in
(345 mm)
5.1 in
(130 mm)
2.1 in
(53.3 mm)
Wire
Barb
Hanger
bar
T-bar
notch
www.lutron.com/finire
610.282.7472