VOLTAGE AND CONTINUITY TESTER
3. Single-pole phase Test
1. The single-pole phase test is only possible when batteries are installed and in good condition.
2. The single-pole phase test starts at an AC voltage of approx. 100V (pole >100V AC).
3. When using single-pole phase tests to determine external conductors the display function may be impaired under certain
conditions (e.g. for insulating body protective equipment on insulation locations).
4. The single-pole phase testing is not appropriate to determine whether a line is live or not. For this purpose, the double-pole
voltage test is always required.
5. Connect both test probes with power source.
6. The LED (5) is illuminated in the display.

4. Continuity Test

The continuity test is only possible when batteries are installed and in good condition. A signal sound is audible for
continuity and the LED for continuity LED
(9) is illuminated.

5. Rotary Field Indication

The voltage testers are equipped with a double-pole rotary field indicator.
The safety measures as mentioned in paragraph 2.0 have to be met.
The rotary phase indication is always active. The symbols R or L are always displayed. However, the rotary direction can
only be determined within a threephase system. Here, the instrument indicates the voltage between two external conductors.
Connect the instrument test probe with the supposed phase L2 and the handle test probe with the supposed phase L1.
The voltage and the rotary field direction are displayed.