• Indication of air quality
Air quality indicator (12) is located at the front panel (C) of the appliance. The 3 LED lights will indicate the air
quality level:
Air Quality
Excellent
Slight pollution
Moderate pollution
High pollution
Extreme pollution

CARE AND MAINTENANCE

Before performing any maintenance work, switch off the air purifier using the on/off button (1).
Use a damp cloth to clean the surface of the product.
Important: Do not use any abrasive materials, as these may damage the surface of the product.
Frequency of cleaning/replacing the filters :
Filter
Pre filter
2in1 Active Carbon & Allergy+ filter
NanoCaptur+ filter
These figures are based on tests in which the air purifier is used for 8 hours per day in quiet mode.
You may need to replace the filters more often depending on the air quality and how often the air purifier
is used. The filter replacement indicator (7)
will receive a notification on your mobile application. To replace the filters, please refer to the section
"Disassembling / Reassembling filters".
Important! When the filter replacement indicator (7)
order to know which filter has to be replaced. If two filters must be changed, please change them one by one.
Change the second filter only after changing the first one and after resetting the first filter.
• The pre-filter can be cleaned with a vacuum cleaner or rinsed in water.
Important: Resetting the filter
After replacing the filter, press the mode button (2)
Performing a force reset:
If you replace a filter before the end of its lifespan, press the mode button (2)
filter settings.
Caution :
If the granules of the filter become "white opaque", the filter needs to be removed from the purifier until the
granules become transparent again.
If the opaque appearance persists, the filter needs to be changed.
If the granules become "crumbly", the filter needs to be changed.
The appliance efficiency can be reduced if the pre-filter is not cleaned regularly.
Never use a pre-filter that is still damp.
The pre-filter is the only filter which can be cleaned with water and re-used.
The 2in1 Active Carbon & Allergy+ Filter cannot be cleaned and re-used, so never wash with water. It must be
replaced at the end of its lifespan.
If the nanocaptur+ filter granules become opaque red and/or crumbly, the filter should be changed.
For optimum performance of the appliance, only use filters provided by Rowenta.
Please note: certain filters may emit a temporary slight odor, due to the transport and storage conditions. This
odor will vanish and is not dangerous for people.
10
Air quality indicator color
Blue
Green
Yellow
Orange
Red
Clean/replace
Frequency
Clean
Every 2 months
Replace
Every 12 months
Color changing (see
color chart on filter)
Replace
or every 12 months in
case of no saturation.
will turn on when the filters need to be replaced and you
turns on, please check on the mobile application in
for 3 seconds to reset the filter settings.
for 3 seconds to reset the
Pollution sensors
The particle sensor need to be cleaned regularly (every 2 months) and appropriately.
Make sure you turn off and unplug the appliance before cleaning the pollution sensors and follow the
recommendations below:
1. Clean the air inlet and outlet using a soft brush or cloth.
2. Open the sensor cover located on the left hand side of the appliance.
3. Lightly wet a cotton swab and remove any dust from the lens and the inlet/outlet. Wipe dry using a dry cotton
swab.
4. Clean the sensor using a soft brush or vacuum cleaner.
IMPORTANT:
Never use a detergent or metal object to clean the sensors.
The efficiency of the sensors may be reduced if not cleaned regularly.
Cleaning frequency varies depending on the operating environment of the appliance. If it is used in a
Filter codes
dusty environment, clean the sensors more frequently.
XD6231

STORAGE

When you are not using the appliance, store it in a cool, dry place with ambient conditions no higher than 95°F
XD6087
(35°C) 70%RH.

IN THE EVENT OF A PROBLEM

• Do not disassemble the appliance yourself. A poorly repaired appliance may be dangerous for the user.
• Check the troubleshooting table below before contacting an Approved Service Center:
Problem
The appliance does not
switch on.
The air flow does not
change automatically.
The flow is a lot weaker
than before.
There is an unpleasant
smell coming from the air
outlet.
The air quality indicator
does not change color.
Check
Connect the power cord to a plug
Is the power cord connected?
with the correct voltage.
Press the on/off button and select the
Are all the display elements off?
You can use your purifier once the
Is there a power outage?
power turns on again.
Is the appliance in manual mode?
Select the correct operating mode.
Check the filter cleaning and
Does the filter need to be cleaned or
replacement frequencies and clean/
replaced?
replace the filter(s) if necessary.
Check the filter cleaning and
Does the light still indicate poor air
replacement frequencies and clean/
quality?
replace the filter(s) if necessary.
Is the sensor lens covered with dust?
Clean the sensor lens.
EN
Solution
required function.