Power Options - Honeywell T6 Pro Serie Notice D'installation

Masquer les pouces Voir aussi pour T6 Pro Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Power options

A
S
L/A
S
O/B
Y
W
AUX
2
Y
E
2
G
W
C
K
U
R
U
Rc
Setting Slider Tabs
Set R Slider Tab.
• Use built-in jumper (R Slider Tab)
to differentiate between one or two
transformer systems.
• If there is only one R wire, and it is
connected to the R, Rc, or RH terminal, set
the slider to the up position (1 wire).
• If there is one wire connected to the R
terminal and one wire connected to the Rc
terminal, set the slider to the down position
(2 wires).
NOTE: Slider Tabs for U terminals should be
left in place for T6 Pro models.
Wiring terminal designations
Input for wired indoor
S
or outdoor sensors
(TH6320U and
TH6220U only)
S
Compressor contactor
Y
(stage 1)
Compressor contactor
Y2
(stage 2)
G
Fan
24VAC common. For 2
transformer systems,
C
use common wire from
cooling transformer.
U
Unused
U
* Terminal can be jumped using Slider Tab. See "Setting Slider Tabs" above.
Insert R and C wires into
designated terminals
for primary AC power (C
terminal is optional if
batteries are installed,
but it is recommended).
Remove wires by
depressing the terminal
tabs.
L/A
- A
O/B
AUX -
W2
E
W
K
R
Rc
Heat Pump fault input
(Common (C) wire required
for LA/A)
Changeover valve
Auxiliary heat
Heat (stage 2)
Emergency Heat
Heat (stage 1)
Unused
24VAC power from heating
transformer*
24VAC power from cooling
transformer*
3
Insert AA
batteries for
primary or
backup power.
UWP Mounting System
R/Rc slider tab
Note: Not all
terminals may be
used, depending
on the system
type that is being
wired. The most
commonly used
terminals are
shaded.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Th6320u2008Th6220u2000Th6210u2001

Table des Matières