Original accessories/attachments
■
Use only the accessories and additional
equipment that are specified in the operating
instructions and are compatible with the ap
pliance.
Residual risks
Even if you operate this power tool properly,
there will still be residual risks. The following
risks can occur in relation to the power tool's
design and structure
■
Lung damage, if no suitable breathing protec-
tion is worn .
■
Hearing damage, if no suitable hearing protec-
tion is worn .
■
Damage to health caused by vibrations if the
appliance is used for extended periods or is not
properly used and maintained .
■
Crushing injuries, if you come into contact with
rotating parts .
■
Risk of electric shock! Hold the appliance by the
insulated handles when you are carrying out
work during which the deployed tool may come
into contact with concealed power cables or its
own power cable . Contact with a live wire can
also make metal parts of the appliance live and
could result in an electric shock .
WARNING!
►
The power tool creates an electromagnetic
field during operation . This field can, in cer-
tain circumstances, impair active or passive
medical implants . To reduce the risk of fatal
injuries, we recommend that people with
medical implants consult their doctor and the
manufacturer of the medical implant before
operating this machine .
■
16
│
GB │ IE
All manuals and user guides at all-guides.com
Before use
WARNING! RISK OF INJURY!
Always remove the plug from the
power socket before working on
the power tool.
Fitting the stirrers
♦
Pull back the locking collars 3 on the two tool
holders 5 . Insert the colour-marked ends of the
two stirrers 4 into the correspondingly coloured
tool holders 5 . Check that the stirrers 4 are
firmly fitted by twisting and pulling on them .
Removing the stirrers
♦
Pull back the locking collars 3 on the two tool
holders 5 to remove the two stirrers 4 .
Fitting the stand/hanger (see fig . B)
♦
Fit the stand/hanger 0 to the handle 1 using
the four supplied Phillips screws q (see fig . C) .
Use a Phillips screwdriver to do this (not sup-
plied) .
Using the stand/hanger
♦
Use the stand/hanger 0 to hang up the appli-
ance or stand it on the floor . In this way, you
can protect it from soiling .
PDRW 1800 A1