STEP 3 Check water supply requirements and cautions
• The hot water supply line pressure must be between 20 ~ 120 psi (140 ~ 830 kPa).
• Adjust the water heater to deliver water between 120 °F (49 °C) ~ 149 °F (65 °C).
- The dishwasher must be connected to a hot water supply between 120 °F
(49 °C) ~ 149 °F (65 °C). This temperature range provides the best washing result
and shortest cycle time. Temperature should not exceed 149 °F (65 °C) to prevent
damage to dishes.
- Ensure that the water supply valve is turned off before connecting the hot water
supply line to the dishwasher.
- Seal the hot water supply line connections using teflon tape or sealing compound to
stop any water leakage.
- The drain hose connected to the dishwasher must be run through the hole in the
side wall so it can be connected to the drain outlet of the sink. When you install the
dishwasher, ensure there is nothing on the drain hose and be careful not to damage
it during the installation process.
Figure 2
Power cable
Hot Water
Supply Line
Inlet valve
DW9900R_DD68-00208B-00_EN.indd 13
4¼-6¼ in.
(110-160 mm)
Dishwasher bottom
English 13