9.6. Trouble Shooting and Remedy

Fault
No pressure /
Insufficient or No water supply
too low pressure
Rinsing nozzle is not installed
Insufficient or
No supply of diluted products
No foam creating
Product is not suitable
Incorrect nozzle
Non-return valve is blocked
Injector /mixing chamber
blocked
No spray
No supply of dilute products
sanitising
Non-return valve is blocked
Injector /mixing chamber is
blocked
In case of errors/troubles not mentioned above, please contact your local
service technician for further assistance.
18
Cause
Open water supply valve
(See 5.1 – Closing valve)
Place rinsing nozzle
Consult directions for use of
dosing unit
Choose suitable product
Place foam nozzle
Clean or replace non-return
valve
Clean nozzle
Consult directions for use of
dosing unit
Clean or replace non-return
valve
Clean Injector /mixing chamber
Remedy