The delivered bracket should be
secured to the wall by the enclosed
screws and corresponding dowels
•
It is VERY important that the wall
bracket is mounted with ALL of the
enclosed 4 screws!
•
The wall bracket should be mounted
on the wall according to the above
description and the unit is hung on to
the bracket. The hose and Product
holders should be mounted after-
wards.
•
The operation button must be mount-
ed after mounting of the cover.
•
The screw on the button must be
aligned with the small hole on the
shaft.
•
Press the button while fastening the
screw. (See illustration 110006080
and 110006213)
110006213
14
6.4. Transportation
For secure transportation of the unit, we
recommend always to ensure, that the
unit can not slide or tip. The unit might
have to be secured with straps.
Transportation of the unit only in horison-
tal position: The unit must not be placed
on the front where you find the operation
panel. Neither can it be placed on top or
bottom where connections and outlets
are mounted.
In case the unit is moved at a tempera-
ture of approx or below 0°C (32°F), you
must always make sure that the the unit
has been fully emptied for water. If this is
not the case, you may damage the unit.
6.5. Vibrations
Hand-arm vibrations according to ISO
5349-1.
110006080
6.6. Water Connection
•
•
•
•
•
•
Before the unit is connected to
the water supply pipe, the supply
line should be rinsed carefully
in order to remove coarse
impurities and metal shavings.
The connection for water must
be made on the side of the unit.
(see layout drawing)
Minimum internal diameter of the
supply pipe must be at least ½"
external (ø16 mm internal).
The pressure loss in the supply
line must be held as low as
possible by:
•
avoiding long supply pipes
•
mounting low pressure
resistance ball valves and
•
avoiding fittings with high
pressure loss.
When installing the piping, take
care to avoid air traps.
All pipe connections to the unit
must be screwed connections
ensuring simple maintenance
and dismantling of the station.