OPERATION – TIME FLOW VERSIONS
• References 763BOX+763000, 763BOX+763040, 763BOX+763041 and 763BOX+763030:
press the anti-blocking push-button to operate. Automatic timed shut-off.
OPERATION – DUAL CONTROL VERSIONS (Fig. M page 22)
• 464SBOX+464000 and 464PBOX+464006: 2 operating modes.
- voluntary activation by pressing the anti-blocking push-button and automatic timed shut-off.
The push-button operates autonomously: the flush operates even if the electricity supply fails.
- or automatic activation when the user leaves.
Infrared electronic detection: detection delay is 10 seconds.
• 7 seconds rinse time (can be adjusted from 5 - 10 seconds depending on flush volume required or type of WC pan
(image ).
• "Intelligent" automatic rinsing (image ) :
- Use time less than 2 minutes: low flush volume
- Use time greater than 2 minutes: large flush volume
The timing can be adjusted from 1 to 3 minutes.
• In the event of the product being reset (30 seconds without supply), it restarts and carries out an opening
and closing cycle on the solenoid valve. The red LED is only visible flashing on the front during the first 10 user
detections.
• To avoid interference from infrared beams do not install the electronic mixer or tap opposite a mirror or bright object.
• Do not install two electronic mixers or taps opposite each other.
• Hygienic duty flush every 24 hours after the last use (can be adjusted to 12 hours or OFF) (image ).
INSTALLATION
• For the UK market, the flush valve must be supplied by a centralised tank and a pump that ensures a dynamic
pressure of 1.2 bar minimum.
• Pressure: 1 bar (100kPa) to 5 bar (500kPa), we recommend 3 bar (300kPa).
• Required operating flow rate: 1 l/sec.
• The electrical installation must conform to local Electrical Regulations/Standards.
THE INTEGRITY OF THE SEALS BETWEEN THE WALL PLATE AND THE WALL MUST BE CHECKED AT LEAST
ONCE A YEAR, AND MORE FREQUENTLY IF NECESSARY, REPLACE THEM IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT
UK: 01491 821821. ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
Our products are compatible with grey and sea water as long as both are filtered and have a pH number between
6.5 and 9.5.
ADJUSTING THE FLOW RATE
The flow rate can be adjusted from 2 to 9L:
• Time flow versions 763BOX+763000, 763BOX+763040, 763BOX+763041 and 763BOX+763030:
turn the lever on the stopcock (Fig. K page 12, 15 or 19) as well as the adjustment cog-wheel behind actuator
plate (Fig. L1 and L2 page 12, 15 or 19) until the required flush volume is achieved.
• Dual control versions 464SBOX+464000 and 464PBOX+464006: turn the lever on the stopcock
(Fig. L1 page 22) as well as the adjustment cog-wheels behind actuator plate (Fig. L2 page 22) and/or the length
of the rinse (Fig. M, image page 22) until the required flush volume is achieved.
31
EN