Installation And Use; Switching Off - Skytec 160.463 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTALLATION AND USE

Unpack the unit. Do not connect the mains lead of the remote control yet. Connect the lead
of the remote control fitted with the 5-pin connector to the rear panel of the fog machine. Fill
the tank via a suitable funnel. Then plug the unit into a mains outlet. This switches the
heating element automatically on. The pre-heating time lasts for about 9 to 10 minutes
depending on the room temperature. Once the temperature is reached, the thermostat clicks
and the green LED on the remote control lights up.
Switch the remote control on or off via the START switch (7). When the
remote control is connected, the red LED (4) lights up.
Once the fog machine has reached the right temperature, the green LED (5)
will light up. The unit can be controlled manually via the MANUAL button (8).
Switch the timer function on via the TIMER switch (6). When this function is
switched on, the yellow LED (3) lights up. When the remote control is in
timer mode, the intervals and the duration of the fog production can be set
via the potmeters 1 & 2. CONTINUAL (1) sets the duration of the fog
production between 0.5 & 10 seconds. INTERVAL< (2) sets the interval time
between two fog productions between 15 & 240 seconds. It is recommended
to produce fog with short pauses. Thus the temperature remains at level and
the thermostat does not switch off.
LOCATION
Place the fog machine at a location where it can be easily filled.
Choose a location where nobody can touch the opening nozzle and which is not close to
inflammable objects. The fog machine must always be placed horizontally or at an angle of
less than 15 degrees.

SWITCHING OFF

Switch the unit off by unplugging it from the mains. Otherwise the 700W heating element
continues to draw current.
SPECIFICATIONS
Power supply: .......................................................................230 Vac / 50 Hz
Capacity: ..................................................................................... 70 m³ / min
Heating element: .................................................................................700 W
Tank capacity: ........................................................................................ 1.0 l
Dimensions (hxwxd): .....................................................235 x 208 x 525 mm
Weight: ................................................................................................ 8.9 kg
Specifications and design subject to changes without prior notice
Do not attempt to make any repairs yourself. This would invalid your warranty.
Do not make any changes to the unit. This would also invalid your warranty.
The warranty is not applicable in case of accidents or damages caused by inappropriate use or disrespect of the warnings
contained in this manual.
SkyTronic UK cannot be held responsible for personal injuries caused by a disrespect of the safety recommendations and
warnings. This is also applicable to all damages in whatever form.
All manuals and user guides at all-guides.com

Publicité

Table des Matières
loading

Table des Matières