Mark Hole Locations; Mark And Cut Vent Opening - Samsung NK30B3500US/AA Guide D'instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions
3. Using a flat head screwdriver, remove the appropriate power supply
knockout.

Mark Hole Locations

1. Determine and clearly mark a vertical centerline on the wall and
cabinet bottom.
A
To wire through top:
1. Mark a line distance (A) from the right of the centerline on the
underside of the cabinet. Mark the point on this line that is 2" (5.08
cm) from the rear wall. Drill a
the underside of the cabinet at this point.
A. Centerline
" (2.2 cm) diameter hole (B) through
7
8
A
A A
2"
(5.08 cm)
B
A. 8
/
" (21.3cm)
2
5
To wire through wall:
1. Mark a line distance (A) from the right of the centerline on the
underside of the cabinet. Mark the point on this line that is
from the underside of the cabinet. Drill a
through the rear wall at this point.

Mark and Cut Vent Opening

For a non-vented (recirculating) installation: skip "Mark and Cut Vent
Opening" step.
For 3¼" x 10" (8.3 x 25.4 cm) Rectangular Vent System
Roof Venting
To make a 4" x 10½" (10.16 cm x 26.7 cm) rectangular cutout on the
underside of cabinet top and bottom:
1. Mark lines 1½" (3.95 cm) and 4
the centerline of the underside of cabinet. Mark lines 5¼" (13.3 cm) to
the right and left of the centerline on the underside of cabinet.
Centerline
Cabinet cutouts
*4
4
(12.25 cm)
2. Use saber or keyhole saw to cut a rectangular opening for vent.
3. Repeat steps 1-3 for the underside of the top of the cabinet.
" (2.2 cm)
7
8
" (2.2 cm) diameter hole (B)
7
8
B
7⁄8"
(2.2 cm)
A
A. 8
/
" (21.3cm)
2
5
" (12.25 cm) from the back wall on
4
5
*1
/
(3.95 cm)
1
2
/
5
/
1
5
4
(13.3 cm)
5
/
1
4
(13.3 cm)
*From wall, not cabinet frame
English
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nk30b3500us

Table des Matières