Working Limits; Technical Data - DGFLOW STEADYPRES V2.0 Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
-
maximum working pressure: 10 bar (140 p.s.i)
-
fluids accepted:
impurities in the liquid, install a strainer upstream
-
fire / explosion: inverters STEADYPRES ARE NOT SUITABLE for operation in environments
with risk of explosion.
-
Maximum ambient temperature: 40 ° c; D
-
minimum ambient temperature: 0 ° C
-
max liquid temperature: 55 ° C
- min liquid temperature:: 0 ° C
-
supply voltage tolerance: + / - 10%
compared to the nameplate data
- flow rates and pressure drops:
figure is represented the loss of load (in
mH2O) through the inverter, to vary the
flow rate
main voltage
supply
output voltage
frequency
enclosure
working position
Current and power table
Model
V in
M/M 8.5
1 ~ 230V
M/M 11
1 ~ 230V
M/M 16
1 ~ 230V
M/T 7
1 ~ 230V
M/T 12
1 ~ 230V
T/T 6
3 ~ 400V
T/T 8
3 ~ 400V

WORKING LIMITS

clean water and liquids that are chemically non-aggressive. If there are
in side

TECHNICAL DATA

230 +/- 10% Vac single-phase
400 +/- 10% Vac three-phase
230 Vac single-phase
230 Vac three-phase
400 Vac three-phase
50 – 60 Hz
IP 65
vertical, with the liquid inlet from the bottom and top exit.
V out
1 ~ 230V
1 ~ 230V
1 ~ 230V
3 ~ 230V
3 ~ 230V
3 ~ 400V
3 ~ 400V
(models M/M e M/T)
(models T/T)
(models M/M)
(models M/T)
(models T/T)
A out
Fuse (A)
8,5
20
11
25
16
25
7
20
12
25
6
no
8
no
P2 max (kW)
P2 max (HP)
1,1
1.5
2,2
1,1
2,2
2,2
3,0
1,5
2.0
3,0
1,5
3,0
3,0
4,0

Publicité