ACTIVATING MULTIPLE ENABLES
When more than one Enable line is activated at the same time, the following rules will apply:
Enable 3 > Enable 2 > Enable 1
If multiple Enables are activated and a the highest priority Enable is programmed for Steady
Burn, then only that Steady Burn color will activate.
For patterns 1-10 only: If you activate multiple flashing Enable lines at the same time the pattern
of the highest Enable wire (3 is highest) will take precedence and each activated flashing color
will cycle though that pattern one at a time with an "Off" time between colors.
For patterns 11-18 only: If multiple Enables are activated and a the highest priority Enable is
programmed for pattern 11-18, then only that Enable will activate.
Any Steady Burn Enable will be de-activated if a higher priority flashing Enable is activated.
ADDITIONAL FUNCTION PROGRAMMING
There are several additional functions that can be accessed through the "shortcuts" that are listed in the chart below.
To set any of them:
1. Connect the BLACK wire to Ground
2. Connect ONE of the Enable wires to Power
3. Hold the GREEN wire to Ground for the time indicated.
Each Enable wire is programmed independently.
Phase 1 / Phase 2 (Patterns 1-10 only)
By default, each Enable is set for Phase 1. If you are synchronizing this light with another
and want the two lights to alternate, use the shortcut shown in the chart to the right to set
the second light for Phase 2.
(See Synchronization section for details)
Steady Burn
Set the corresponding Enable wire for this mode if you want that color to be Steady Burn.
Cruise
Low intensity version of Steady Burn.
Auto-Dim
If this feature is enabled the flashing color/function tied to that particular Enable wire will automatically dim in low light environments (ex. at night).
SYNCHRONIZATION
You can synchronize up to ten total
DO NOT CONNECT WHITE WIRES UNTIL PROGRAMMING
HAS BEEN COMPLETED FOR ALL LIGHTS!!
1. Program the first unit.
2. Program the second light with the same Pattern Type.
Lights with the SAME phase flash together (simultaneous).
Lights with DIFFERENT phases flash opposite one another
(alternate).
3. After programming all lights, cap off the green wires
4. With the power off, connect the white wires together.
5. Test the lights by applying power to all of them at the same time.
RESET TO DEFAULT SETTINGS
To reset all settings to the factory defaults, proceed as follows:
Connect the BLACK wire to Ground
Connect the WHITE wire and any ONE of the Enable wires to Power
Connect hold the GREEN wire to Ground for 9 seconds and release it when the light flashes 3 times.
Disconnect the WHITE wire from Power 1 second later
approved lights.
-3-
FACTORY DEFAULT ENABLE WIRE LEGEND
YELLOW w/BLACK - Enable 3 : Color/Function 3
YELLOW w/GREEN - Enable 2 : Color/Function 2
YELLOW w/RED - Enable 1 : Color/Function 1
FACTORY DEFAULT ENABLE WIRE LEGEND
YELLOW w/BLACK - Enable 3 : Color/Function 3
YELLOW w/GREEN - Enable 2 : Color/Function 2
YELLOW w/RED - Enable 1 : Color/Function 1
PROGRAMMING SHORTCUTS
ALTERNATING
Phase 1
Phase 2
ON
OFF
ADDITIONAL FUNCTION
SYNCHRONIZED
Phase 1
Phase 1