WHITE: Synchronization - AFTER setting the patterns, connect, the white wires from synchronized lights together. Cap off if not used.
YELLOW w/BLACK: Enable 3/ Steady Burn White - Connect to power through a switch using a 5 amp fuse. This is the highest priority and will override the other two functions.
YELLOW w/GREEN: Enable 2 - Connect to power through a switch using a 5 amp fuse. This has a medium priority and will override Enable 1.
YELLOW w/RED: Enable 1 - Connect to power through a switch using a 5 amp fuse. This is the lowest priority and will be overridden by either of the other two functions.
GREEN: Pattern Select - Touch and release to Ground to change patterns.
BLACK: Ground - Connect to a Good Chassis Ground or the negative terminal of the battery.
Note: The total wire length between the two farthest units should be no more than 40 feet.
Standard Programming, Functionality, and Operation
For ease of programming, we recommend using the Android or Apple app (see page 5 for
details). If you do not have access to an Android or Apple device, or prefer to program the
light manually, proceed below.
This section applies to the default functionality of this light. There are also several other advanced
features that can be programmed. Most applications will not require reprogramming of the light,
but you can find these options described in detail under the Advanced Programming section.
The recommended first step is to identify what color is defaulted to each input. To do this:
Connect the BLACK wire to Ground
Touch only one of the Enable wires to power and note which color is activated.
Repeat for each Enable wire.
Please Note The Following
Enable 3 is programmed for steady burn mode by default. If you wish to set it for one of the
flash patterns, please review the Advanced Programming Section.
PATTERN SELECTION
1. Connect the BLACK wire to Ground
2. Connect the corresponding Enable wire to Power (only one at a time).
3. Touch and release the GREEN wire to Ground to scroll through the patterns.
† - SAE J595 approved patterns when properly configured
† - SAE approved patterns when properly configured
† - Modèles approuvés par la norme SAE J595 lorsqu'ils sont configurés correctement.
‡
- SAE approved patterns when programmed for single color only
† - Patrones SAE J595 aprobados cuando se los configura correctamente
Shortcut 1 - Hold GREEN wire to Ground for 3 seconds (light flashes once)
Shortcut 2 - Hold GREEN wire to Ground for 6 seconds (light flashes twice)
All of our DC powered warning lights are polarity sensitive. These lights are polarity protected only if the appropriate
fuse is used. All wires connected to the positive terminal of the battery should be fused at the battery for their rated
load. Testing the light before this fuse is properly installed will void the warranty on the light.
WHITE - Synchronization
YELLOW w/BLACK - Enable 3 (Steady Burn White)
YELLOW w/GREEN - Enable 2
YELLOW w/RED - Enable 1
GREEN - Pattern Select
BLACK - Ground
Wiring
-2-
5 AMP FUSE
BATTERY