Indicator Light Function:
Arrow Symbols (Operation - Blue Light): This light
illuminates and remains illuminated as long as the unit is
operational.
Bucket Symbol (Water Full - Red Light): This light
illuminates under the following conditions;
1. When the internal water tank is not properly installed
inside the cabinet.
2. When the internal water tank is full.Water tank must be
emptied and replaced back in the cabinet before normal
operating conditions can resume.
Water Tank Operation:
Proper installation of the water tank is crucial in
maintaining reliable dehumidifier operation.
The water tank holds accumulated condensed water
routed from the evaporator (cooling) coil during
dehumidifier operation.The water level inside the tank is
controlled by a float switch mechanism that automatically
stops dehumidifier operation when the water level
reaches a pre-determined level.
When the water tank is full and /or incorrectly positioned
inside the cabinet, the (water full) red light flashes and a
signal (beep) sounds for 10 seconds.This condition
results in the immediate shut down of the dehumidifying
system. (compressor cycle terminated, however the fan
motor will continue to operate) The water tank must be
emptied and/or correctly re-positioned before
dehumidifier operation can resume NOTE: It may take
several minutes before operating conditions resume.
This is normal.
IMPORTANT: Never tamper with or attempt to defeat the
float switch mechanism. (as this will result in flooding)
Factory Default Setting:
When the unit is first connected to a power supply, the
electronic circuit board will automatically default to the
following factory settings;
Mode: Dehumidification
Humidity SET AIR Value: 60%
Fan Speed: Low
Custom Default Setting:
When you modify any or all of the factory default settings , your
new settings become the current default settings. When the unit
is switched "Off" or in the event of a power failure, all
your custom settings are retained and then restored once
the power is switched "On"/resumes.
7