Introduction and Features
• The FSS1 a high security door position monitoring
device. It is an ideal alternative for traditional
balanced magnetic reed switches on hinged doors.
• The FSS1 is designed for hinged doors only, and
is not designed to operate on sliding doors or
roller shutter doors.
• The three product models consist of two main
components: the sensor on the door frame and the
magnet array plate on the door.
• Seven magnetic sensors detect the magnetic
footprint from an array of magnets on the magnet
array plate. Six of these sensors determine
polarity, size, strength and position of magnets on
the magnet array plate in relation to the recorded
pattern, and the seventh sensor detects the position
of the magnet array plate
in relation to the FSS1 sensor.
• The FSS1 is not factory calibrated to it's supplied
magnet array plate. The FSS1 is calibrated when
first powered and with the first closing of the door,
when it will record magnetic measurements into
memory. The FSS1 can be recalibrated in case of
door droop or door warp.
• The magnet array plate provides at least 1,820
permutations using at least 4 magnets in different
positions, strength and polarity. In addition, the
magnet array plate position, orientation, door gap
and surrounding material adds more variables,
greatly expanding the base permutations. The
magnetic matrix and door parameters are recorded
by the sensor during calibration.
Specifications
UL 634 High Security Level 2 Specification
Operating voltage
Max current (12 VDC) reduces at higher voltages
Tamper contacts
Alarm contacts
Door gap and door movement trigger
Cable specification (UL)
U.S. and Canadian approvals
Operating temperature, humidity
FSS1 High Security Door
Position Sensor
Pour la portion française, veuillez consulter la page 6
Calibration/Mode
selector
Cover removal
tamper switches
Surface removal
tamper switch
Magnet array
plate
PCB slots for conduit
entry reversal
Cast dimple for
drilling cable entry
Calibration/Mode
selector
½" pipe thread (compatible
with existing installations)
(S Version)
Cover removal
tamper switches
Magnet array plate
10 – 30 volts DC
~ 10 mA secure (normal operating current) 45 mA during initial calibration or
buzzer activated
N.C. and common, 0.2A @ 30V
Two N.O. and common, 0.25A @ 30V output, one on circuit board terminal strip,
second on flying lead designed for access control
¹⁄16" – ⁹⁄32" (1.5 mm – 7 mm) vertical on a hinged door, up to ¹⁹⁄32" (15 mm) door
movement for alarm to trigger
Minimum 22 AWG or 26 AWG solid
UL 634 High Security Level 2, Listed Equipment BP9752
-4 to +140 degrees F (-20 to +60 C), 0 to 85% humidity, suitable for indoor and
outdoor use
Installation Instructions

Publicité

Table des Matières
loading

Sommaire des Matières pour Allegion SCHLAGE FSS1

  • Page 1 FSS1 High Security Door *47381203* Position Sensor 47381203 Installation Instructions Pour la portion française, veuillez consulter la page 6 Introduction and Features • The FSS1 a high security door position monitoring device. It is an ideal alternative for traditional Calibration/Mode balanced magnetic reed switches on hinged doors.
  • Page 2 Models FSS1-F, Flush mount The sensor is flush mounted into the door frame with the magnet array plate flush mounted in the top of the door. The FSS1 sensor must be fully mortised into the door frame using the mounting tabs. FSS1-S, Surface mount with conduit fitting The FSS1-S sensor has a side conduit entry of ¹³⁄16"...
  • Page 3: Mounting The Sensor

    Mounting the sensor FSS1-F, Flush mount The sensor is flush mounted into the door frame with the magnet array plate mounted in the top of the door. The FSS1 sensor must be fully mortised into the door frame. Installation on outward swinging doors is recommended. 1.
  • Page 4: Recalibration

    Calibration The FSS1 is supplied ready for calibration when it is first powered. Rotary switch positions 1. The rotary selection switch must be set to 0, 1, 2, or 3, and the door must be open. Immediate alarm. No buzzer, NORMAL setting. 2.
  • Page 5: Faq And Troubleshooting

    FAQ and Troubleshooting Sensor will not calibrate • Check that voltage is DC and check polarity. • On flush mount sensor (FSS1-F) check that magnet array plate is facing up and orientation marks are aligned. • Check that there are no foreign magnet fields near the sensor. This is indicated by a slow beep when the door is closed. •...
  • Page 6: Fss1 Capteur De Position Pour Porte Haute Sécurité

    FSS1 Capteur de Position Pour Porte Haute Sécurité Instructions d' Installation Introduction et Fonctionnalités • Le FSS1 est un dispositif de surveillance de Étalonnage/sélecteur position pour porte haute sécurité. Il constitue une de mode alternative idéale aux interrupteurs magnétiques à Interrupteurs lames souples équilibrés traditionnels sur les portes d’autoprotection...
  • Page 7 Modèles FSS1-F, Montage encastré Le capteur est encastré dans le cadre de la porte et la plaque de réseau magnétique est encastrée dans le haut de la porte. Le capteur FSS1 doit être entièrement mortaisé dans le cadre de la porte à l’aide des brides de fixation. FSS1-S, Montage en surface avec raccord de conduit Le capteur FSS1-S a une entrée de conduit latérale de 20 mm (13/16 po) et un filetage de tuyau certifié...
  • Page 8: Montage Du Capteur

    Montage du capteur FSS1-F, Montage encastré Le capteur est encastré dans le cadre de la porte et la plaque de réseau magnétique est encastrée dans le haut de la porte. Le capteur FSS1 doit être entièrement mortaisé dans le cadre de la porte. L’installation sur des portes battantes vers l’extérieur est recommandée.
  • Page 9: Réétalonnage

    Étalonnage Le FSS1 est livré prêt pour l’étalonnage lors de sa première mise sous tension. Positions du commutateur rotatif 1. Le sélecteur rotatif doit être réglé sur 0, 1, 2 ou 3 et la porte doit être ouverte. Alarme immédiate. Pas de bouton-signal, réglage NORMAL.
  • Page 10: Questions Fréquemment Posées Et Dépannage

    Questions fréquemment posées et dépannage Le capteur ne s’étalonne pas • Vérifier que la tension est continue et vérifier la polarité. • Sur le capteur encastré (FSS1-F), vérifier que la plaque du réseau magnétique est orientée vers le haut et que les repères d’orientation sont alignés.
  • Page 12 © Allegion 2021 Printed in Australia 47381203 Rev. 03/21-a 9752...

Table des Matières