Introduction and Features
• The FSS1 a high security door position monitoring
device. It is an ideal alternative for traditional
balanced magnetic reed switches on hinged doors.
• The FSS1 is designed for hinged doors only, and
is not designed to operate on sliding doors or
roller shutter doors.
• The three product models consist of two main
components: the sensor on the door frame and the
magnet array plate on the door.
• Seven magnetic sensors detect the magnetic
footprint from an array of magnets on the magnet
array plate. Six of these sensors determine
polarity, size, strength and position of magnets on
the magnet array plate in relation to the recorded
pattern, and the seventh sensor detects the position
of the magnet array plate
in relation to the FSS1 sensor.
• The FSS1 is not factory calibrated to it's supplied
magnet array plate. The FSS1 is calibrated when
first powered and with the first closing of the door,
when it will record magnetic measurements into
memory. The FSS1 can be recalibrated in case of
door droop or door warp.
• The magnet array plate provides at least 1,820
permutations using at least 4 magnets in different
positions, strength and polarity. In addition, the
magnet array plate position, orientation, door gap
and surrounding material adds more variables,
greatly expanding the base permutations. The
magnetic matrix and door parameters are recorded
by the sensor during calibration.
Specifications
UL 634 High Security Level 2 Specification
Operating voltage
Max current (12 VDC) reduces at higher voltages
Tamper contacts
Alarm contacts
Door gap and door movement trigger
Cable specification (UL)
U.S. and Canadian approvals
Operating temperature, humidity
FSS1 High Security Door
Position Sensor
Pour la portion française, veuillez consulter la page 6
Calibration/Mode
selector
Cover removal
tamper switches
Surface removal
tamper switch
Magnet array
plate
PCB slots for conduit
entry reversal
Cast dimple for
drilling cable entry
Calibration/Mode
selector
½" pipe thread (compatible
with existing installations)
(S Version)
Cover removal
tamper switches
Magnet array plate
10 – 30 volts DC
~ 10 mA secure (normal operating current) 45 mA during initial calibration or
buzzer activated
N.C. and common, 0.2A @ 30V
Two N.O. and common, 0.25A @ 30V output, one on circuit board terminal strip,
second on flying lead designed for access control
¹⁄16" – ⁹⁄32" (1.5 mm – 7 mm) vertical on a hinged door, up to ¹⁹⁄32" (15 mm) door
movement for alarm to trigger
Minimum 22 AWG or 26 AWG solid
UL 634 High Security Level 2, Listed Equipment BP9752
-4 to +140 degrees F (-20 to +60 C), 0 to 85% humidity, suitable for indoor and
outdoor use
Installation Instructions