Unloader; Generator; Pre-Start Inspection Procedures - Mi-T-M HVS Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

UNLOADER VALVE
END OF PREPARATION INSTRUCTIONS
16
INSTALLATION & PREPARATION

UNLOADER:

The unloader has been preset at the factory.

GENERATOR:

This unit is equipped with a 115 Volt AC generator. The generator provides
power to the burner, and the control and safety circuits of the machine.
1. Always ensure the burner switch is in the OFF position before starting the
engine. Allow the engine to reach full RPM before turning the burner switch
to the ON position. Failure to do so can damage the generator or burner.
2. Do not spray water at or around generator. Electrocution and/or damage
to the generator, burner, and any auxiliary equipment may result.

PRE-START INSPECTION PROCEDURES:

Before starting the unit, perform the following procedures:
1. Check the oil level in the pump.
2. Inspect the water inlet strainer. Clean or replace if necessary. See "Water
Supply" pg. 15.
3. Check all hose connections to ensure they are securely tightened.
4. Inspect for system water leaks, oil leaks and fuel leaks. If a fuel leak is
found, DO NOT START UNIT! See "Risk of Explosion or Fire" warnings, pgs.
4-5. Be sure that all damaged parts are replaced and that the mechanical
problems are corrected prior to operation of the unit. If you require service,
contact Customer Service.
5. Inspect high pressure hoses for kinking, cuts and leaks. If a cut or leak is
found, DO NOT USE HOSE! Replace hose before starting unit. See "Risk
of Injection" warnings, pg. 6. Be sure that all damaged parts are replaced
and that the mechanical problems are corrected prior to operation of the
unit. If you require service, contact Customer Service.
Operator's Manual