Minimum Position Pressure Regulators
DESCRIPTION
The SP970A, B, C and D Manual and Minimum Position
Pressure Regulators provide regulated pressure to a
1-9/16
(40)
® U.S. Registered Trademark
Copyright © 2002 Honeywell •All Rights Reserved
SP970A, B, C and D Manual and
2-1/4
(57)
2-1/2
(63)
FRONT VIEW
Fig. 1. SP970A and C dimensions in in. (mm).
2-1/16 (62)
3-1/4 (83)
FRONT VIEW
Fig. 2. SP970B and D dimensions in in. (mm).
controlled device such as a pneumatic damper operator.
It provides either manually set pressure or manually set
minimum pressure with variable maximum pressure.
Figs. 1 and 2 show approximate dimensions.
7/8
(22)
SP970C 3-7/8 (98)
SP970A 3-1/2 (89)
SIDE VIEW
4-1/2
(114)
1
3-1/2 (89)
(25)
7/8
SIDE VIEW
(22)
INSTALLATION INSTRUCTIONS
1-7/8
(48)
1-1/2
(38)
C4857
C4858
95-7237EF

Publicité

Table des Matières
loading

Sommaire des Matières pour Honeywell SP970A

  • Page 1 It provides either manually set pressure or manually set minimum pressure with variable maximum pressure. The SP970A, B, C and D Manual and Minimum Position Pressure Regulators provide regulated pressure to a Figs. 1 and 2 show approximate dimensions.
  • Page 2: Before Installation

    SP970A, B, C AND D MANUAL AND MINIMUM POSITION PRESSURE REGULATORS BEFORE INSTALLATION NOTES: √ The scaleplate, knob and two mounting nuts are furnished with SP970A and C. SP970A and C only √ Do not mount the knob during installation.
  • Page 3: Engineering Data

    Operating Pressure (Switch and Pilot) Range: Normal Main: 18 psi (124 kPa) All SP970A and C models are calibrated at 8 psi (55 kPa) Branch: 3 to 15 psi (21 to 103 kPa) when the calibration mark (center punch) on the shaft is Pilot: 3 to 15 psi (21 to 103 kPa) centered at the bottom of the molded V.
  • Page 4 SP970A, B, C AND D MANUAL AND MINIMUM POSITION PRESSURE REGULATORS SP970C and D: Four Port Switches to the SP970A, B as a pressure regulator. When the external signal is greater than the spring load, the spring These minimum position devices have a separate dead...
  • Page 5: Sélecteurs De Pression Manuels Et À Position Minimale Sp970A, B, C Et D

    (1-7/8) (1-1/2) SP970C 98 (3-7/8) (2-1/2) SP970A 89 (3-1/2) CF4857 VUE DE FACE VUE DE PROFIL Fig. 1. Encombrement des SP970A et C, en mm (po). (4-1/2) (1-9/16) 89 (3-1/2) 62 (2-1/16) 83 (3-1/4) (7/8) VUE DE FACE VUE DE PROFIL CF4858 Fig.
  • Page 6: Modèles Sp970A Et C Seulement

    SÉLECTEURS DE PRESSION MANUELS ET Ω POSITION MINIMALE SP970A, B, C ET D AVANT D'INSTALLER CE REMARQUES : √ L'échelle, le bouton et les deux écrous PRODUIT… de montage sont fournis avec les SP970A et C. √ Ne pas poser le bouton au moment de Modèles SP970A et C seulement...
  • Page 7: Vérification Et Essai De Tous Les Modèles

    SÉLECTEURS DE PRESSION MANUELS ET Ω POSITION MINIMALE SP970A, B, C ET D Tableau 1. Identification des orifices. Sélecteur de Sélecteur à position pression SP970A minimale SP970A SP970B SP970C, D SP92 SP93 Canal. princ. Pilote √ √ Canal. sec. Purge √...
  • Page 8 SÉLECTEURS DE PRESSION MANUELS ET Ω POSITION MINIMALE SP970A, B, C ET D SP970C et D : Sélecteurs à quatre orifices que les SP970A et B, c'est-à-dire comme un sélecteur de pression. Lorsque la pression du signal extérieur est Ces appareils à position minimale ont une chambre plus élevée que la force du ressort, la force du ressort est...

Ce manuel est également adapté pour:

Sp970bSp970cSp970d

Table des Matières