STEP 31: Top and bottom of the Door Panel (8) can
be adjusted to improve the magnet seal when closing
the door. Loosen the Steel Nuts (5J) and move the
Door Panel (8) left or right.
STEP 33: Apply clear mildew resistant silicone on
the outside of tub shower from the top to bottom of
the Wall Jambs (1, 1A).
STEP 35: Finished Door Installation. If the door leaks make sure that it was sealed with clear mildew resistant silicone
as specified in the installation manual.
We want you to be completely satisfied with our products and service. If you have any comments or
The company reserves the right to change models and specifications without notice.
All manuals and user guides at all-guides.com
suggestions, please call
1-800-MIROLIN
STEP 32: If the Magnet Strip (10) is not closing tight:
Use a piece of wood, tap the wood block with a mallet
to adjust and align the magnet seals in the areas
required.
STEP 34: Apply clear mildew resistant silicone tub
caulking around the Left, Right Fixed Panels (2,2A,)
Bottom Sill (4) outside the shower from wall to wall.