STARTING THE ENGINE
1. RECOIL STARTER
1. Remove all the loads out of the output.
2. Turn the fuel valve to the "ON" position.
3. Turn the AC circuit breaker to the "OFF" position.
4. Turn the choke lever to the "CLOSE" position.
Don't close the choke when starting the engine in warm state
5. Turn the generator switch to the "ON" position.
6. Pull the starter grip until compression is felt, then pull briskly.
7. Turn the choke lever to the "OPEN" position after the engine is warm.
8. Don't use electric apparatus before setting circuit breaker to the "ON" position.
2. ELECTRIC STARTING (PMV7000)
1. Remove all the loads out of the output.
2. Turn the fuel valve to the "ON" position.
3. Turn the choke lever to the "CLOSE" position.
Don't close the choke when starting the engine in warm state.
4. Turning the generator switch to electric starting position.
5. After starting engine, immediately release generator switch and generator switch can
automatically return to open position.
6. Turn the choke lever to "OPEN" position after the engine is warm.
Turn the generator switch to electric starting position for more than 5 seconds can
damage the starting motor. If failing to start, release the switch and wait 10 seconds
before operating it again.
If the speed of the starting motor drops fast after a period of time, it means that the
battery should be recharged.
STOPPING THE ENGINE
1. Turn the AC circuit breaker to the OFF position.
2. Turn the generator switch to the OFF position.
3. Turn the fuel valve to the OFF position.
To stop the engine in an emergency, turn the generator switch to the OFF position.
11