1.
Before measurement, make sure that the capacitor to be
measured has been discharged.
2.
For a high capacitance measurement, it may take about 30
seconds for the meter to measure capacitance.
3.
To improve the accuracy of low-capacitance measure-
ments, subtract the residual capacitance of the meter and
the test leads.
Measuring Frequency and Duty Cycle
Connect the black test lead to the "COM" jack and the red test
1.
lead to the "VΩHz" jack .
Set the range switch to "Hz%" position.
2.
Press the "Hz%" button to select frequency or duty cycle
3.
measurement.
Connect the test leads across the source or load to be
4.
measured.
Read the reading.
5.
NOTE:
For frequency measurements, the voltage of the input signal
should be between 1 and 20 V RMS.
For duty cycle measurements, the voltage of the input signal
should be between 3 and 10 V P-P.