Assembly

1
Location of the air compressor
1. Locate the air compressor in a clean, dry, and well ventilated area.
2. Located the air compressor at least 18 in. (0.5 m) away from the wall or other
obstructions that will interfere with the ow of air.
3. Locate the air compressor as close to the main power supply as possible to avoid
using long lengths of electrical wiring. NOTE: Long lengths of electrical wiring could
cause power loss to the motor.
4. The air lter must be kept clear of obstructions which could reduce air ow to the air
compressor.
2

Breaking in the pump

NOTICE: Risk of property damage. Serious damage may result if the
following break-in instructions are not closely followed.
This procedure is required before the air compressor is put into service and when the check
valve or a complete compressor pump has been replaced.
1.
Make sure the Auto/Off switch (A) is in the "Off" position.
2.
Check oil level in pump. See Oil paragraph in the Maintenance section for instructions.
3.
Recheck all wiring. Make sure wires are secure at all terminals connections. Make sure all
contacts move freely and are not obstructed.
4.
Open the drain valve (F) fully to permit air to escape and prevent air pressure build up in
the air tank during the break-in period.
5.
Move the Auto/Off switch (A) to "Auto" position. The compressor will start.
6.
Run the air compressor for 20 minutes. Make sure the drain valve and all air lines are
open so there is only a minimal air pressure build-up in tank.
7.
Check all air line ttings and connections/piping for air leaks by applying a soap solution.
Correct if necessary.
NOTICE: Minor leaks can cause the air compressor to overwork, resulting in
premature breakdown or inadequate performance.
8.
Check for excessive vibration. Readjust or shim air compressor feet, if necessary.
9.
After 20 minutes, close the drain valve. The air receiver will ll to "cut-out" pressure and
the motor will stop.
The air compressor is now ready for use.
9