Storage; Troubleshooting - Husky 723883 Guide D'utilisation Et D'entretien

Compresseur d'air portatif de 114 litres (30 gallons)
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
Maintenance (continued)
9
Air compressor Head Bolts
- Torquing
The air compressor pump head bolts should
be kept properly torqued. Check the torques
of the head bolts after the rst ve hours of
operation.
Torque to 14-16 ft-lbs (19–21.7 Nm).

Storage

Before you store the air compressor, make sure you do the following:
1.
Review the Maintenance section on the preceding pages and perform scheduled
maintenance as necessary.
2.
Drain water from air tank. See To Drain Tank under Operation.
WARNING: Water will condense
in the air tank. If not drained,
water will corrode and weaken
the air tank causing a risk of air
tank rupture.

Troubleshooting

Problem
Possible Cause
Compressor does
not run.
10
Disassembly or service of the air compressor
beyond what is covered in this manual is
not recommended. If additional service is
required, contact 1-888-43-HUSKY for further
assistance.
Tank has insuf cient
pressure.
No electrical power.
Blown stop/house fuse.
Tripped shop/home
breaker.
Thermal overload is open.
16
Additional Service
Solution
When the tank pressure drops, the
compressor will turn on to cut-in
pressure.
Verify wiring connection inside
pressure switch and terminal box
area.
Replace the shop/house fuse.
Reset the shop/home breaker and
determine the underlying cause.
Place the Auto/Off switch in the
"Off" position.
Allow the motor to cool.
Depress the red reset button on
the motor.
Place the Auto/Off switch in the
"Auto" postion to restart the
motor.

Publicité

Table des Matières

Dépannage

loading

Ce manuel est également adapté pour:

C301h

Table des Matières