Troubleshooting - Piscine Center PLATINIUM 095 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. Troubleshooting

7.1 Error code display on LED wire controller
Error
Malfunction
Code
High pressure
EE 01
failure
Low pressure
EE 02
failure
'ON'
or
Water flow failure
EE03
Over heating
protection for
EE 04
water
temperature (T2)
in heating mode
Exhaust
temperature (T6)
EE 05
too high
protection
Controller
EE 06
malfunction
Reason
1. High pressure switch in bad connection
or failure
2. Ambient temperature is too high
3. Water temperature is too high
4. Water flow is too low
5. Fan motor speed is abnormal or fan
motor has damaged
1. Low pressure switch in bad connection
or failure
1. EEV has blocked or pipe system is
jammed
2. Motor speed is abnormal or motor has
damaged
3. Gas leakage
1. Water flow switch is in bad connection
2. Water flow switch is damaged
3. No/ Insufficient water flow.
1. Low water flow
2. Water flow switch is stuck and the
water supply is cut off
3. T2 sensor is abnormal
1. Lack of gas
2. Low water flow
3. Piping system has been blocked
4. Exhaust temp. Sensor failure
1. Wire connection is not good or
damaged signal wire
2. Controller failure
1. Check the wiring for high pressure
switch or change a new one
2.Check the water flow or water pump
3. Check the fan motor
4. Check and repair the piping system
1. Check the wiring for low pressure
switch or change a new one
2. Check the EEV and piping system
Check the motor
3. Through the high pressure gauge to
check the pressure value
1. Check the wiring for water flow
switch
2. Change the water flow switch
3. Check the water pump or the
waterway system
1. Check the water way system
2. Check the water pump or water
flow switch
3. Check T2 sensor or change another
one
1. Check the high pressure gauge, if
too low, fill with some gas
2. Check the waterway system and
water pump
3. Check the piping system if there
was any block
4. Change a new exhaust temp. sensor
1. Check and re-connect the signal
wire
2. Change a new signal wire
3. Turn off electricity supply and
restart machine
4. Change a new controller
65
Solution

Publicité

Chapitres

Table des Matières
loading

Table des Matières