Parameter Setting - Piscine Center PLATINIUM 095 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.2.6
Parameter checking
Select
and press
Code
d0
IPM mould temperature
d1
Inlet water temp.
d2
Outlet water temp.
d3
Ambient temp.
d4
Frequency limitation code
d5
Piping temp.
d6
Gas exhaust temperature
d7
Step of EEV
d8
Compressor running frequency
d9
Compressor current
d10
Current fan speed
d11
Error code for last time
Remark:
d4: Frequency limitation code,
0: No frequency limit;
2: Overheating or overcooling frequency limit;
8: Drive voltage frequency limit;
6.2.7

Parameter setting

Select
and press
Note: Long press
Code
Name
P0
Mandatory defrosting
P3
Water pump
P7
Water temp. calibration
to enter, press
Condition
to enter, press
for 15s to set P14, P18.
Scope
0-1
0-1
-9~9
and
to check d0-d11 value.
Scope
0-120℃
-9℃ ~99℃
-9℃ ~99℃
-30℃ ~70℃
0,1,2,4,8,16
-30℃ ~70℃
0℃ ~C5℃ (125℃ )
0~99
0~99Hz
0~30A
0-1200 (rpm)
All error code
1: Coil pipe temperature limit;
4: Drive Current frequency limit;
16:Drive high temperature frequency limit
and
to choose P0-P18 value and press
Default
0: Default normal operation
0
1: mandatory defrosting.
1:Always running;
0
0:Depends on the running of compressor
0
Default setting: 0
59
Remark
Real testing value
Real testing value
Real testing value
flash if Real value<-9
Real testing value
flash if Real value<-9
Real testing value
N*5
Real testing value
Real testing value
Real testing value
to set.
Remark