10. Trouble Shooting
Having trouble?
Noise is louder than specifications.
Nothing appears in the wireless remote controller display, the display is
faint, or signals are not received by the indoor unit unless the remote con-
troller is close.
The operation lamp near the receiver for the wireless remote controller on
the indoor unit is flashing.
Warm air blows from the indoor unit intermittently when heating mode is off
or during fan mode.
11. Specifications
I PLFY Series
Model
Power source
Capacity
Dimension (Grille)
Net weight (Grille)
Fan Airflow range
(Low-Middle2-Middle2-High) WET
Noise level
(Low-Middle2-Middle2-High)
I PKFY Series
Model
Power source
Capacity
Dimension
Net weight
Fan Airflow range
(Low-Middle2-Middle2-High) WET
Noise level
(Low-Middle2-Middle2-High)
Model
Power source
Capacity
Dimension
Net weight
Fan Airflow range
(Low-High)
Noise level
(Low-High)
PLFY-P12NAMU-E PLFY-P15NAMU-E PLFY-P18NAMU-E PLFY-P24NAMU-E PLFY-P30NAMU-E PLFY-P36NAMU-E
Cooling <BTU/h>
12,000
Heating <BTU/h>
13,500
H
<inch>
W
<inch>
D
<inch>
<Ibs>
49(11)
DRY
<CFM>
390-420-460-490
<CFM>
350-380-410-440
<dB(A)>
24-27-28-30
PKFY-P06NAMU-E PKFY-P08NAMU-E PKFY-P12NGMU-E PKFY-P15NGMU-E
Cooling <BTU/h>
6,000
Heating <BTU/h>
6,700
H
<inch>
W
<inch>
D
<inch>
<Ibs>
DRY
<CFM>
170-180-200-210
<CFM>
160-170-180-190
<dB(A)>
32-33-35-36
PKFY-P18NFMU-E PKFY-P24NFMU-E PKFY-P30NFMU-E
Cooling <BTU/h>
18,000
Heating <BTU/h>
20,000
H
<inch>
W
<inch>
D
<inch>
<Ibs>
DRY
<CFM>
490-640
WET
<CFM>
440-570
<dB(A)>
Here is the solution. (Unit is operating normally.)
I The indoor operation sound level is affected by the acoustics of the par-
ticular room as shown in the following table and will be higher than the
noise specification, which was measured in an echo-free room.
High sound-
absorbing rooms
Broadcasting
Location
studio, music
examples
Noise levels
I The batteries are low.
Replace the batteries and press the Reset button.
I If nothing appears even after the batteries are replaced, make sure that
the batteries are installed in the correct directions (+, –).
I The self diagnosis function has operated to protect the air conditioner.
I Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure
to provide the dealer with the model name.
I When another indoor unit is operating in heating mode, the control valve
opens and closes occasionally to maintain stability in the air conditioning
system. This operation will stop after a while.
* If this will cause an undesirable rise in the room temperature in small
rooms, etc., stop the operation of the indoor unit temporarily.
Single 208/230V 60Hz
15,000
18,000
17,000
20,000
10-3/16(1-3/16)
33-1/16(37-3/8)
33-1/16(37-3/8)
49(11)
53(11)
420-460-490-570
490-530-570-640
380-410-470-530
380-500-530-600
27-28-30-32
27-28-31-33
Single 208/230V 60Hz
8,000
12,000
9,000
13,500
11-5/8
32-1/8
6-1/4
19
280-340-370-410
250-300-330-370
32-36-40-42
Single 208/230V 60Hz
24,000
30,000
27,000
34,000
13-3/8
55-1/8
66-1/8
9-1/4
53
62
780-990
700-890
39-45
46-49
Normal rooms
Reception room,
hotel lobby, etc.
room, etc.
3 to 7 dB
6 to 10 dB
24,000
30,000
27,000
34,000
11-3/4(1-3/16)
53(11)
66(11)
530-570-640-710
710-810-920-990 780-880-990-1060
500-530-600-670
670-770-870-930 730-830-930-1000
28-30-33-34
34-36-40-41
15,000
17,000
13-3/8
39
9-1/4
35
Low sound-
absorbing rooms
Office, hotel
room
9 to 13 dB
36,000
40,000
66(11)
37-40-43-44
17

Publicité

Table des Matières
loading

Table des Matières