Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Easy-Change Water Dispenser/Icemaker Water Filter
Installation and Operating Instructions
Model IC-1000
Specifications
Pressure Range:
30–125 psi (2.1–8.62 bar)
Temperature Range: 40–100°F (4.4–37.7°C)
Rated Service Flow:
0.5 gpm (1.9 Lpm)
Filter Capacity:
500 gallons (1893 L)
Turbidity:
5 NTU max
Parts Included:
• Filter head with built-in bracket and compression fittings
• 1000R filter cartridge
• Screws for mounting bracket
Tools and Materials Required
• Phillips screwdriver
• File
(Copper tubing only)
• Pipe cutter or hacksaw
(copper tubing only)
• Utility knife
(for plastic tubing)
Optional Materials
•Shut off valve
• Saddle tap valve w/ shut off
• 1/4" plastic or copper tubing, or flexible
hose
• Fittings
• Towel
• Pencil
•Tape Measure
• T-Flush valve
(Required when used only with an icemaker)
See Diagram below. This valve is installed
after the filter, so it can be flushed to remove
carbon fines or release pressure before
removing cartridge.
Filter Outlet
To Water
Dispenser/Icemaker
To Drain
Provide an air gap between
end of tube and drain to
prevent contamination
T-Flush valve is required only when this
unit is used with an icemaker.
Technical Support: 1-800-645-5426
(M-F 7:30 am - 5:00 pm CST)
Precautions
WARNING:
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
CAUTION: This filter must be protected from freezing, which can cause cracking
of the filter and water leakage.
CAUTION: Because of the product's limited service life and to prevent costly
repairs or possible water damage, we strongly recommend that the
head of the filter be replaced every ten years. If the head of your
filter has been in use for longer than this period, it should be
replaced immediately. Date the top of any new head to indicate the
next recommended replacement date.
CAUTION: Turn off water supply to head without cartridge if it must be left
unattended for an extended period of time.
NOTE:
• For cold water use only.
• Make certain that installation complies with all state and local laws and
regulations.
• The contaminants or other substances removed or reduced by the selected
cartridge are not necessarily in your water. Ask your local water municipality
for a copy of their water analysis, or have your private well tested by a
reputable water testing lab.
• After prolonged periods of non-use (such as during a vacation) it is
recommended that the system be flushed thoroughly. Let water run for 2-3
minutes before using.
• The filter cartridge used with this system has a limited service life. Changes
in taste, odor, color; and/or flow of the water being filtered indicate that the
cartridge should be replaced.
The IC-1000 is Tested and Certified by NSF International to NSF/ANSI Standard
42 for the aesthetic reduction of Taste and Odor, Chlorine, and Particulate Class
I. Standard 53 for the reduction of Cyst, Lead, Lindane, Atrazine and Turbidity.
Installation
• For standard installation on 1/4-inch copper, plastic or flexible hose cold water
line.
• Please read all instructions and precautions before installing and using your
IC-1000 water dispenser Icemaker Filter
• Numbered diagrams correspond with numbered steps
• Instructions refer to standard installation on existing water line to refrigerator.
Before installation, make sure there is enough slack in existing water line to
allow refrigerator to be moved out from the wall.
11/03 146507 Rev A

Publicité

Table des Matières
loading

Sommaire des Matières pour Culligan IC-1000

  • Page 1 The IC-1000 is Tested and Certified by NSF International to NSF/ANSI Standard 42 for the aesthetic reduction of Taste and Odor, Chlorine, and Particulate Class Filter Outlet I.
  • Page 2 Installation Continued 1. Mounting the Filter System (A) Turn off the cold water supply to the refrigerator and dispense the water from the refrigerator door until water flow stops to release the pressure in the pipes before starting installation. Place a tray or towels under the cold water line to catch the excess water after the pipes are cut. NOTE: Before starting installation, turn off the icemaker in the refrigerator and store the ice cubes in a clean container in the freezer.
  • Page 3: Filter Cartridge Replacement

    (6) Flush water through refrigerator door or T-Flush valve for 5 minutes to remove carbon fines. Check for leaks before leaving installation. Performance Data Model IC-1000 Important Notice: Read this performance data and compare the capabilities of this system with your actual water treatment needs. It is recommended that, before installing a water treatment system, you have your water supply tested to determine your actual water treatment needs.
  • Page 4: Replacement Parts

    T-Flush valve until water and airflow stops. For date of delivery. Culligan will replace any part which in Culligan’s opinion is defective, unless: copper or plastic tubing, loosen the compression nut and pull the tubing from the (1) any part of the system has been subjected to any type of tampering, alteration, or improper brass fitting.
  • Page 5: Caractéristiques Techniques

    à une machine à glaçons seule. existante alimentant un réfrigérateur. Avant la pose, assurez-vous que le tuyau Le modèle IC-1000 a été essayé et homologué par NSF International selon la d’eau existant est assez long pour pouvoir éloigner le réfrigérateur du mur.
  • Page 6 1. Pose du système de filtrage (A) Avant de commencer la pose, couper l’arrivée d’eau froide alimentant le réfrigérateur et dépressurisez la tuyauterie en faisant couler l’eau à la fontaine réfrigérée située sur la porte du réfrigérateur jusqu’à ce que l’eau arrête de couler. Placez un plateau ou des serviettes sous le tuyau d’eau froide pour recueillir l’eau qui s’égoutte après avoir coupé...
  • Page 7: Remplacement De La Cartouche Filtrante

    Date Revised: August 21, 2002 en suspension au moins 10000 ≥ 85% 99,8% Trademark/Model Designation Replacement Elements (0,5 à –<1µm) particules/ml Culligan IC-1000 1000 R Class I Culligan SY-1000 1000 R Culligan SY-1000S 1000 R Norme 53 Affectant la santé Culligan RV-1000...
  • Page 8: Dépannage

    Dépressurisez le système en coupant l’arrivée d’eau au filtre et en faisant couler de tion ne couvre pas le coût de transport des pièces. Culligan ne peut être tenu pour responsable l’eau à la fontaine réfrigérée montée sur la porte du réfrigérateur ou par le robinet des dégâts survenus pendant le transport.

Table des Matières