Avent ISIS iQ DUO Mode D'emploi page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ISIS
Manual Pump – Parts Guide
You may want to use the ISIS Manual Pump when you need a cord-free alternative to
the ISIS iQ DUO
. While the ISIS Manual Pump uses many of the same parts as the ISIS
iQ DUO, please note the parts shaded in green are specific to the ISIS Manual Pump.
u
v
h
g
d
e
f
ISIS Manual Pump
Cleaning the ISIS Manual Pump
Caution: Do not use antibacterial cleaners or detergents when cleaning breast pump parts.
Every time before use (including first use):
Clean all parts of the ISIS Manual Pump on the top rack of the dishwasher, or in warm
soapy water and rinse. The pump should be sanitized after every use. All parts of the
ISIS Manual Breast Pump are sterilizer safe. Sanitize in a steam sterilizer (electronic,
electric or microwave), or by boiling in water for 10 minutes.
15
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
Parts specific to the ISIS
Manual Pump are included
in a separate bag:
u
Clear pump cover
w
v
Silicone diaphragm with a stem
Forked handle
w
c
c
White valve
Pump body
d
e
Reusable base (4 oz/125 ml)
f
Stand (same as
)
h
g
Let-down Massage Cushion
Funnel cover (same as )
h
Wash your hands thoroughly. Click the white valve
1
into the pump body so that it fits securely into the
small round hole. Make sure the pointed side of the
valve is facing down.
Fit the silicone diaphragm with stem into the
2
pump body. Ensure a perfect seal around the rim
by pressing down with your fingers. (This is easier
if assembled while the diaphragm is wet.)
Twist the reusable base onto the pump
3
body until securely in place. To ensure the
TM
pump is completely stable, insert the
f
pump base into the stand.
Fit the Let-down Massage Cushion
4
pump funnel. Secure the rim of the Let-down
Massage Cushion around the funnel, so that there
are no gaps. (This is easier if assembled while the
Let-down Massage Cushion is wet.)
5
Place the forked end of the handle under the
rounded tip of the diaphragm stem. Push down
gently on the handle until it clicks into place.
6
Click the pump cover onto the pump body.
Assembling the ISIS
Manual Pump
Wash and sanitize all parts before use. See section titled
'Cleaning the ISIS Manual Pump' on page 15.
white stand
TM
onto the
16

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour Avent ISIS iQ DUO

Table des Matières