FINALIZING THE SETUP (CPU AND GPU COOLING)
For combined CPU & GPU water cooling please follow these
recommended installation steps and port configuration:
1. Locate the correct ports. It is mandatory to use the correct
ports, as marked on the picture (see Figure 1).
2. Install the four (6) appropriate CORSAIR XF G1/4 BSPP
threaded-type fittings (not included) into the appropriate
distro plate ports and tighten them by hand as shown in
Figure 2. Do not use any tools (i.e. pliers).
3. Install the enclosed CORSAIR G1/4 Temperature Sensor Plug
(D) into the G1/4 port located on the bottom of the unit.
4. Close the remaining open (unused) ports with the included
CORSAIR G1/4 plugs (C) and tighten them using a Plug
Tool (F). Refrain from using a screwdriver as it may result in
damage to the surface of the plugs!
Figure 1
CPU OUTLET
CPU INLET
GPU OUTLET
GPU INLET
Figure 2
RADIATOR
OUTLET
D
RADIATOR
C
INLET
F
5
CONNECTING THE PUMP AND USING THE INTEGRATED DIGITAL
RGB ILLUMINATION
A CORSAIR iCUE Commander PRO or Lighting Node PRO
(either) is required in order to use the integrated RGB illumination
on the XD7 RGB. CORSAIR iCUE software is used to program
the visual effects. CORSAIR iCUE Commander PRO is required
for automatic control of the pump and for monitoring the liquid
temperature using iCUE software suite.
The XD7 RGB Distro Plate / Pump Unit can be connected to
the appropriate CORSAIR controller either directly or "daisy"-
chained with other CORSAIR addressable RGB component(s).
1. Identify the correct RGB connector on the reservoir-pump unit
(Figure 1).
2. Insert the RGB connector in a CORSAIR iCUE Commander
PRO port or Lighting Node PRO port (Figure 2).
3. Download and install CORSAIR iCUE software suite from
the following website: https://www.corsair.com/icue.
Configure visual and lighting effects by following the manual
for iCUE software.
4. Connect the XD7 RGB's pump 4-pin fan connector into Fan
Port #6 on your CORSAIR iCUE Commander PRO (Figure 3).
5. Connect the XD7 RGB's temperature sensor into temperature
Port #1 on your CORSAIR iCUE Commander PRO (Figure 4).
6. Connect the XD7 RGB's main power cable by plugging in a
4-pin Molex connector from your power supply (Figure 5).