3.
driver.com.port
the serial port name for the evcc's, commaseperated list.
o
driver.com.baud
the baudrate of the serial port of the evcc.
o
use.pp.as.cable.detection=false
use PP on the connector to detect a cable or use CP
o
must.send.tokens.of.evcc=false
if set false, no tokens from the evcc are handled
o
modem.reset.connector=1
on which connector the modem hard reset must be executed.
o
mode3.max.cp.voltage.deviation=0.05
The percentage of the allowed deviation of the CP 12v line.
o
driver.check.heartbeats=true
Enables heartbeat checking of the evcc to the lccl. The log line is the heartbeat for
o
the evcc to lccl.
driver.check.heartbeats.interval=60
The number of seconds between heartbeats check of the connector steering.
o
driver.check.heartbeats.maxtime.missed=360
The number of seconds that the heartbeat can be missed before the error
o
'Mode3_unresponsive' is set.
connector.evcc.config.enabled=true
Enables the configuration of the evcc, The lccl will configure the attached evcc to
o
the correct layout and behavior.
connector.evcc.config=LCCPROd3F2C
The config name of the evcc. For possible options see at_wbtype=type command of
o
the connector stearing.
connector.evcc.1.config=LCCPROd3F2C
The config name of the evcc for connector 1.
o
connector.evcc.lockmotor=2
configures the lockmotor of the evcc during startup
o
connector.evcc.connectorID.lockmotor=2
configures the lockmotor of the evcc during startup FOR a specific connector only.
o
connector.evcc.cable.attached=false
If set to true there is not socket but the cable is attached on the chargepoint
o
The PP value and thus the max allow current trhough the cable is configured on the
o
dipswitches
connector.evcc.connectorID.cable.attached=false
connector.evcc.diode.check=false
By default now is the nodiode check disable, to enable it, set this to true
o
connector.evcc.connectorID.diode.check=false

Connector steering config:

0 = DOSTAR DSIEC-SL (P5, PNB, ...), 1 = Menekes, 2 = DOSTAR DSIEC-ELB (MRA,
...), 9 = use with type 1, this will disable the use of the lock.