2.
http.listening.port=12800
the port number on which the lccl must deploy its webserver.
o
transaction.stop.with.error
if true and an error occurs during a transaction, the transaction will be stopped,
o
otherwise the transaction is suspended.
transaction.when.offline.stop.in.state.A
default false. If set to true the transaction is stopped when the chargepoint is offline
o
and the state changes to A: cable removed from the car side.
transaction.remotelystarted.when.offline.stop.in.state.A false
default false. If set to true the transaction is stopped when the chargepoint is offline
o
and the transaction is remotely started and the state changes to A: cable removed
from the car side. With stopping the transaction the cable will also be unlock at the
chargepoint, and can the user retrieve its cable.
transactions.keep.max
default 20, the maximum of transactions to keep on disk so it can be viewed on
o
page /admin/transactionsList.html.
config.preset=none
When this setting is set, the configuration for this preset is set on the chargepoint. The
o
preset has several configuration entries defined which will be applied.
chargepoint.upgrade.as.backprocess=true
enables the upgrade procedure that runs in the background; it will start
o
downloading the zip file but only start installing with all connectors are available.
chargepoint.upgrade.as.backprocess.scheduled.to.off=false
When upgrading as a backproces do set the connectors to scheduled to off, this
o
way when a connector becomes available nobody else can start a new transaction
until ALL transactions are stopped on all connectors AND after a reboot
chargepoint.report.meter.0=true
for FKN and MRA_FKN, the chargepoint can report the metervalues of connector 0.
o
chargepoint.report.failed.meter.0=false
If reading the meter fails, should the chargepoint be set to error state and no longer
o
allow any charging.