Page 1
All manuals and user guides at all-guides.com AutoView ® 3100/3200 Installer/User Guide...
Page 2
All manuals and user guides at all-guides.com USA Notification Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Page 4
All manuals and user guides at all-guides.com Instructions This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. Dangerous Voltage This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Chapter 3: Local Port Operation................... 11 Controlling Your System at the Local Port..................11 Viewing and selecting ports and servers .................. 11 Viewing the status of your AutoView 3100/3200 switching system.......... 13 Navigating the OSCAR Interface ..................... 15 Configuring OSCAR Interface Menus ..................... 16 Managing server tasks using the OSCAR interface..............
Page 6
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide TABL E OF CONTEN TS Using the top option bar ......................40 Launching a KVM session ......................41 Managing an AutoView switch web interface device ............... 41 Managing local accounts......................42 Managing device properties .....................
Page 7
All manuals and user guides at all-guides.com Table of Contents Appendices........................67 Appendix A: Flash Upgrades......................67 Appendix B: Using AVRIQ-SRL modules ..................69 Appendix C: UTP Cabling ....................... 73 Appendix D: Technical Specifications ..................... 75 Appendix E: Sun Advanced Key Emulation ..................77 Appendix F: Technical Support .......................
Page 8
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide...
Page 9
All manuals and user guides at all-guides.com LIST OF TA BLES List of Tables Table 3.1: Main Dialog Box Functions ................... 12 Table 3.2: OSCAR Interface Status Symbols ................... 13 Table 3.3: OSCAR Interface Navigation Basics ................15 Table 3.4: Setup Features to Configure the OSCAR Interface............16 Table 3.5: OSCAR Interface Status Flags ..................
Page 10
All manuals and user guides at all-guides.com viii AutoView 3100/3200 Switch Installer/User Guide...
Page 11
All manuals and user guides at all-guides.com L IST OF F IGURES List of Figures Figure 1.1: Example AutoView 3100/3200 Switch Configuration ............ 3 Figure 2.1: Basic AutoView 3100 Switch Configuration ..............7 Figure 3.1: OSCAR Interface Main Dialog Box................12 Figure 3.2: OSCAR Interface Setup Dialog Box ................
Page 12
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide...
PS/2 and USB keyboards and mice • accessibility to target devices across a 1000BaseT LAN port • accessibility to target devices directly through a local port The AutoView 3100/3200 switches give you flexible target device management control from anywhere in the world.
On-board Web Interface The AutoView 3100/3200 switch also provides a built-in web interface to handle all KVM switching needs. Featuring secure “point-and-click” web browser-based access to control any attached device, the AutoView switch web interface provides a Video Viewer window that allows you to control the keyboard, monitor and mouse functions of the connected target device in real time.
All manuals and user guides at all-guides.com Chapter 1: Product Overview AutoView 3200 Switch Shown Ethernet Analog User ® (OSCAR Graphical Digital User User Interface) (Computer with Internet Browser) Figure 1.1: Example AutoView 3100/3200 Switch Configuration...
• Use only with grounded outlets at both the target device and monitor. When using a backup Uninterruptible Power Supply (UPS), power the target device, the monitor and the AutoView 3100/ 3200 switch from the UPS. NOTE: The AC inlet is the main power disconnect.
One CAT 5 patch cable for network connectivity (4-pair UTP, up to 10 meters) NOTE: All references to IQ modules in this document use the AVRIQ module as a default. The AutoView 3100/ 3200 switches support Avocent AVRIQ, DSRIQ and DSAVIQ modules as well as Avocent Integrated Access...
Configure the AutoView 3100/3200 switch using the console menu interface. • Make the appropriate mouse setting adjustments. Figure 2.1 on page 7 illustrates a basic configuration for the AutoView 3100/3200 switch, using the AutoView 3100 switch as a model for the example.
All manuals and user guides at all-guides.com Chapter 2: Installation Analog User Network Digital User AutoView 3100 Switch Power Ports Cord 1-16 Local USB Connections Servers 1-16 AVRIQ/IAC modules, PS/2, USB*, Sun and serial adaptors are available. Figure 2.1: Basic AutoView 3100 Switch Configuration...
AutoView 3100/3200 Switch Installer/User Guide Connecting the AutoView 3100/3200 switch hardware NOTE: The AutoView 3100/3200 switch may be rack mounted in a 1U configuration. The AutoView 3100/ 3200 switch does not support a 0U configuration. To connect and power up your AutoView 3100/3200 switch: 1.
Verifying the Connections AutoView 3100/3200 switch The front panel of the AutoView 3100/3200 switch features LEDs indicating the status of the Ethernet connection: • The green LED, labeled Link, illuminates when a valid connection to the network is established at a rate of 1000 Mbps and blinks when there is activity on the port.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide Adjusting Mouse Settings on Target Devices Before a computer connected to the AutoView 3100/3200 switch can be used, you must set the target mouse speed and turn off acceleration. For machines running Microsoft Windows ®...
Local Port Operation Controlling Your System at the Local Port The AutoView 3100/3200 switch includes a local port on the back. This port enables you to connect a keyboard, monitor and mouse to the switch for direct access. The AutoView 3100/3200 switch uses the OSCAR graphical user interface, which has intuitive menus to configure your system and select target devices.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide Figure 3.1: OSCAR Interface Main Dialog Box Table 3.1: Main Dialog Box Functions Button Function Log Out Disconnect the KVM and user sessions. Clear Clear all offline AVRIQ modules.
AVRIQ module. Selecting target devices Use the Main dialog box to select target devices. When you select a target device, the AutoView 3100/ 3200 switch reconfigures the keyboard and mouse to the settings for the selected target device.
Page 26
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide To select the previous target device: Press and then . This key combination toggles you between the previous Print Screen Backspace and current connections. To disconnect from a target device:...
All manuals and user guides at all-guides.com Chapter 3: Local Port Operation Navigating the OSCAR Interface This table describes how to navigate the OSCAR interface using the keyboard and mouse. Table 3.3: OSCAR Interface Navigation Basics Keystroke Function Print Screen Opens the OSCAR interface.
Erases characters in a text box. Configuring OSCAR Interface Menus You can configure your AutoView 3100/3200 switching system from the Setup dialog box within the OSCAR interface. Select the Names button when initially setting up your switching system to identify target devices by unique names. Select the other setup features to manage routine tasks for your target devices from the OSCAR interface menu.
All manuals and user guides at all-guides.com Chapter 3: Local Port Operation Figure 3.2: OSCAR Interface Setup Dialog Box Assigning target device names Use the Names dialog box to identify target devices by name rather than by port number. The Names list is always sorted by port order.
Figure 3.3: OSCAR Interface Names Dialog Box NOTE: If new AVRIQ modules are discovered by the AutoView 3100/3200 switch, the on-screen list will be automatically updated. The mouse cursor will change into an hourglass during the update. No mouse or keyboard input will be accepted until the list update is complete.
All manuals and user guides at all-guides.com Chapter 3: Local Port Operation Figure 3.4: OSCAR Interface Name Modify Dialog Box 2. Type a name in the New Name box. Names of target devices may contain all printable characters. 3. Click OK to transfer the new name to the Names dialog box. Your selection is not saved until you click OK in the Names dialog box.
AutoView 3100/3200 Switch Installer/User Guide Figure 3.5: OSCAR Interface Devices Dialog Box When the AutoView 3100/3200 switch discovers a cascade switch, the numbering format changes from an AutoView port only to [AutoView port]-[switch port] to accommodate each target device under that switch.
All manuals and user guides at all-guides.com Chapter 3: Local Port Operation To assign a device type: 1. In the Devices dialog box, select the desired port number. 2. Click Modify to open the Device Modify dialog box. Figure 3.6: OSCAR Interface Device Modify Dialog Box 3.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide Figure 3.7: OSCAR Interface Menu Dialog Box To choose the display order of target devices: 1. Select Name to display target devices alphabetically by name. -or- Select EID to display target devices numerically by EID number.
All manuals and user guides at all-guides.com Chapter 3: Local Port Operation Controlling the status flag The status flag displays on your desktop and shows the name or EID number of the selected target device or the status of the selected port. Use the Flag dialog box to configure the flag to display by target device name or EID number, or to change the flag color, opacity, display time and location on the desktop.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide To determine how the status flag is displayed: 1. Select Name or EID to determine what information will be displayed. 2. Select Displayed to show the flag all the time or select Timed to display the flag for only five seconds after switching.
All manuals and user guides at all-guides.com Chapter 3: Local Port Operation Figure 3.10: OSCAR Interface Broadcast Dialog Box NOTE: Broadcasting Keystrokes - The keyboard state must be identical for all target devices receiving a broadcast to interpret keystrokes identically. Specifically, the Caps Lock and Num Lock modes must be the same on all keyboards.
From the Commands dialog box, clear the Broadcast Enable checkbox. Using Scan mode In Scan mode, the AutoView 3100/3200 switch automatically scans from port to port (target device to target device). You can scan up to eight target devices, specifying which ones to scan and the number of seconds that each will display.
All manuals and user guides at all-guides.com Chapter 3: Local Port Operation 4. Type the first few characters of a target device name or port number to scan. The first matching target device will appear in the line. -or- Press the following keyboard commands in the Name, Port or Time column to move through the list of target devices available to scan.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide 3. Select Scan Enable in the Commands dialog box. 4. Click X to close the Commands dialog box. NOTE: Scanning will begin as soon as the Scan Enable button is selected.
This command sequence works only when the user is connected to a target device. Setting the keyboard country code NOTE: Using a keyboard code that supports a language different from that of your AutoView 3100/3200 switch firmware will cause incorrect keyboard mapping.
A soft reboot may be performed without waiting 90 seconds. Managing server tasks using the OSCAR interface From the OSCAR interface Commands dialog box, you can manage your AutoView 3100/3200 switching system and user connections, enable the Scan and Broadcast modes and update...
Begin scanning target devices. Set up a target device list for scanning in the Setup dialog box. User Status View and disconnect users. Display View version information for the AutoView 3100/3200 switch as well as view and upgrade Versions firmware for individual AVRIQ modules. Reset PS/2...
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide To access the OSCAR interface Commands dialog box: 1. If the OSCAR interface is not open, press to open the Main dialog box. Print Screen 2. Click Commands to open the Commands dialog box as shown in Figure 3.15.
All manuals and user guides at all-guides.com Chapter 3: Local Port Operation Figure 3.16: OSCAR Interface User Status Dialog Box To disconnect a user: 1. If the OSCAR interface is not open, press to open the Main dialog box. Print Screen 2.
Reset command. The Reset command sends a hot-plug sequence to the target device which causes the mouse and keyboard settings to be sent to the AutoView 3100/3200 switch. With communication re-established between the target device and the AutoView 3100/3200 switch, functionality is restored to the user.
All manuals and user guides at all-guides.com Chapter 3: Local Port Operation Figure 3.18: OSCAR Interface Version Dialog Box 3. To view individual AVRIQ module version information, click AVRIQ to open the AVRIQ Selection dialog box shown in Figure 3.19. Figure 3.19: IQ Selection Dialog Box 4.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide For more information on loading firmware, refer to Appendix A. Figure 3.20: IQ Version Dialog Box 5. Click X to close the IQ Version dialog box.
Web Interface Operations Overview of the AutoView 3100/3200 Switch Web Interface In addition to the OSCAR on-screen interface, the AutoView 3100/3200 switch provides a built in web interface to handle all KVM switching needs. The AutoView switch web interface provides secure “point-and-click”...
When a user has been logged in and authenticated, the Avocent AutoView Explorer window appears. From the AutoView Explorer window, users may view, access and manage their AutoView 3100/3200 switch. The window may also be used to specify system settings and change profile settings.
AutoView switch web interface window, print a web page, log out of a software session or access the Avocent Technical Support help page. The name of the logged in user appears on the left side of the top option bar.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide Using the top option bar Bookmarking a window (Internet Explorer only) The AutoView Explorer window contains a bookmark icon and text in the top option bar. Bookmarking a window will add a link to the window in the Favorites drop-down menu. You may select the link at any time to quickly access the bookmarked window.
Upgrading AVRIQ modules The IQ Flash upgrade feature allows you to update AVRIQ modules with the latest firmware available from Avocent. This update can be performed using the AutoView switch web interface or the OSCAR interface. After the Flash memory is reprogrammed with the upgrade, the AutoView 3100/3200 switch performs a soft reset, which terminates all AVRIQ module sessions.
AVRIQ module to be returned to the factory for repair. Rebooting the appliance Periodically, such as after an upgrade, you may need to reboot the AutoView 3100/3200 switch. To reboot the AutoView 3100/3200 switch remotely: 1.
3. Edit the user account as needed, then click Save. Managing device properties Viewing and changing appliance configuration information The AutoView 3100/3200 switch can report most device properties directly through the AutoView switch web browser. NOTE: Users can view all appliance information, but only Administrators can change settings.
Page 56
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide Table 4.2: Viewing Appliance Information (Continued) To do this: Select this: Display a list of devices attached to the AutoView Appliance - Connections 3100/3200 switch Appliance - Properties - Identity View the unit’s part number, serial number and...
All manuals and user guides at all-guides.com CHA PTER The Video Viewer About the Video Viewer Window The Video Viewer is used to conduct a KVM session with the target devices attached to the AutoView switch. When you connect to a device using the Video Viewer, the target device desktop appears in a separate window containing both the local and the target device cursor.
Best Color), changing the color settings can increase video performance. For optimal video performance over a slower network connection, Avocent recommends a color setting such as Grayscale/Best Compression or Low Color/High Compression. See the the Adjusting color depth section on page 51 for more information.
All manuals and user guides at all-guides.com Chapter 5: The Video Viewer Video Viewer Window Features Figure 5.1 shows the Video Viewer window areas, and descriptions follow in Table 5.1 on page 48. Figure 5.1: Video Viewer Window (Normal Window Mode)
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide Table 5.1: Video Viewer Window Description Letter Description Title Bar: Displays the name of the server being viewed. When in Full Screen mode, the title bar disappears and the server name appears between the menu and toolbar.
All manuals and user guides at all-guides.com Chapter 5: The Video Viewer Changing the toolbar You can choose the amount of elapsed time before the toolbar hides in the Video Viewer window when it is in show/hide state (that is, not locked in place by the thumbtack). To specify a toolbar hide time: 1.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide Adjusting the view Using menus or Task buttons in the Video Viewer window, you can do the following: • Align the mouse cursors. • Refresh the screen. •...
All manuals and user guides at all-guides.com Chapter 5: The Video Viewer To enable or disable full screen mode: 1. To enable Full Screen mode, click the Maximize button. -or- Select View - Full Screen from the Video Viewer window menu. The desktop window disappears and only the accessed device desktop is visible.
To manually adjust the video quality of the window: NOTE: The following video adjustments should be made only on the advice and with the help of Avocent Technical Support.
All manuals and user guides at all-guides.com Chapter 5: The Video Viewer Table 5.2: Manual Video Adjust Dialog Box Descriptions Letter Description Letter Description Image Capture Width Pixel Noise Threshold Pixel Sampling/Fine Adjust Automatic Video Adjustment Image Capture Horizontal Position Refresh Image Image Capture Vertical Position Adjustment bar...
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide You can modify Noise Threshold and Priority Threshold values if you are using standard video compression. You can also modify Block Noise Threshold and Pixel Noise Threshold values. You can restore default threshold values by clicking Auto Adjust Video.
All manuals and user guides at all-guides.com Chapter 5: The Video Viewer NOTE: If the device does not support the ability to disconnect and reconnect the mouse (almost all newer PCs do), then the mouse will become disabled and the device will have to be rebooted. Cursor type The Video Viewer window offers five appearance choices for the local mouse cursor.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide To select a key for exiting single cursor mode: 1. Select Tools - Session Options from the Video Viewer window menu. -or- Click the Session Options button. The Session Options dialog box appears.
All manuals and user guides at all-guides.com Chapter 5: The Video Viewer The Session Options dialog box appears. 2. Click the Mouse tab. 3. To use one of the preconfigured settings, check the appropriate radio button. -or- To set custom scaling: Click the Custom radio button to enable the X and Y fields.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide NOTE: The Japanese keyboard ALT-Han/Zen keystroke combination is always sent to a remote server regardless of the screen mode or keyboard pass-through setting. To specify keyboard pass-through: 1. Select Tools - Session Options from the Video Viewer window menu.
All manuals and user guides at all-guides.com Chapter 5: The Video Viewer To capture the Video Viewer window to your clipboard: Select File - Capture to Clipboard from the Video Viewer window menu. -or- Click the Capture to Clipboard button. The image data is saved to the clipboard.
Page 72
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide...
Terminal Operations The Console Menu Each AutoView 3100/3200 switch may be configured at the appliance level through the Console menu interface accessed through the SETUP port on the back of the switch. All terminal commands are accessed through a terminal or PC running terminal emulation software.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide Figure 6.1: Console Main Menu 2. Once the Console Main menu displays, type and press to access the Network Enter Configuration menu shown in Figure 6.2.
DHCP is selected, the IP Address, Netmask and Default Gateway settings are automatically assigned to the AutoView 3100/3200 switch and may not be modified by a user. If you are using the DHCP option, please configure your DHCP server to provide an IP address to the AutoView 3100/3200 switch and then skip step 5.
Defaults, Reset Appliance and Exit. Each is discussed in this section. Security configuration The AutoView 3100/3200 switch contains an internal database that may be used by the AutoView Remote Operations software, the local port or the CONSOLE port if the DSView software server is unavailable.
4. You will be prompted to enter the number of the user you wish to delete. Type the user’s number then press Enter 5. You will be prompted to confirm deletion of the user from the AutoView 3100/3200 switch database. Type and press to remove the user.
Page 78
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide...
3. Use the supplied null modem cable to DB9 (male) adaptor to connect a terminal or PC running terminal emulation software (such as HyperTerminal) to the SETUP port on the back panel of the AutoView 3100/3200 switch. The terminal should be set to 9600 bps, 8 bits, 1 stop bit, no parity and no flow control.
Page 80
NOTE: If the green LED on the back panel of the switch blinks continuously, the switch is in recovery mode. To recover from a failed Flash upgrade: 1. Visit http://www.avocent.com/support and download the latest Flash firmware from Avocent. 2. Save the Flash upgrade file to the appropriate directory on the TFTP server.
The AVRIQ-SRL module is a serial-to-VGA converter which permits VT100-capable devices to be viewed from the AutoView 3100/3200 switch local port or by using the on-board web interface. The actual serial data is not accessed, but is merely displayed. All serial data coming from the target device is displayed in a VT100 window, placed into a video buffer and sent to the AutoView 3100/3200 switch as though it came from a VGA target.
Page 82
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide • Enter Sends: This option enables you to specify the keys that are transmitted when Enter pressed. Available options are <CR> (Enter), which moves the cursor to the left side of the screen, or <CR><LF>...
Page 83
All manuals and user guides at all-guides.com Appendices To configure an AVRIQ-SRL module: 1. Press . The Configuration Screen will appear. Ctrl-F8 2. Select a parameter to change. You can navigate the Configuration Screen using the Up Arrow keys. Down Arrow 3.
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide To use History mode: 1. Press . The mode will display as History. Ctrl-F9 2. Press one of the following key combinations to perform the indicated action: •...
Appendices Appendix C: UTP Cabling The AutoView 3100/3200 switching systems utilize UTP cabling. This appendix discusses various aspects of connection media. The performance of a AutoView 3100/3200 switching system depends on high quality connections. Poor quality or poorly installed or maintained cabling can diminish AutoView switching system performance.
Page 86
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide Cabling installation, maintenance and safety tips The following is a list of important safety considerations that should be reviewed prior to installing or maintaining your cables: • Keep all CAT 5 runs to a maximum of 10 meters each.
All manuals and user guides at all-guides.com Appendices Appendix D: Technical Specifications Table D.1 lists the technical specifications for the AutoView 3100/3200 switch. Table D.1: AutoView 3100/3200 Switch Product Specifications Server Ports Number 16 (AutoView 3100/3200 switches) AVRIQ-PS/2, AVRIQ-USB, AVRIQ-USB2, AVRIQ-USB2L, AVRIQ-VSN (Sun...
Page 88
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide Table D.1: AutoView 3100/3200 Switch Product Specifications (Continued) Power Supply AC-input Power 40 W maximum AC-input Range 100 - 240 VAC AC-input Current Rating 0.5A 18 AWG three-wire cable, with a three-lead IEC-320...
All manuals and user guides at all-guides.com Appendices Appendix E: Sun Advanced Key Emulation Certain keys on a standard Type 5 (US) Sun keyboard can be emulated by key press sequences on a PS/2 keyboard. To enable Sun Advanced Key Emulation mode and use these keys, press and hold and then press the key.
AVRIQ-USB modules. These keys function normally if your Sun servers are attached to the AutoView 3100/3200 switch using an AVRIQ-VSN or AVRIQ-WSN module. Table E.2 lists the keyboard mapping that will take place when an AVRIQ-USB module is used in this setting.
Appendix F: Technical Support Our Technical Support staff is ready to assist you with any installation or operating issues you encounter with your Avocent product. If an issue should develop, follow the steps below for the fastest possible service. To resolve an issue: 1.
Page 92
All manuals and user guides at all-guides.com AutoView 3100/3200 Switch Installer/User Guide...
Page 93
All manuals and user guides at all-guides.com...
Page 94
All manuals and user guides at all-guides.com...
Page 96
All manuals and user guides at all-guides.com Instructions Ce symbole est destiné à attirer votre attention sur la présence de consignes importantes liées au fonctionnement et à la maintenance (entretien) dans la documentation accompagnant le matériel. Tension dangereuse Ce symbole est destiné à vous avertir de la présence de « tensions dangereuses » non isolées à l’intérieur de l’appareil pouvant être suffisamment élevées pour constituer un risque de choc électrique pour les individus.
Page 97
Contrôle du système par la voie locale.................... 11 Visualisation et sélection des voies et des serveurs..............11 Visualisation de l’état du système de commutation AutoView 3100/3200 ....... 13 Navigation dans l’interface OSCAR ....................15 Fonctions de configuration de l’interface OSCAR ................16 Gestion des tâches des serveurs à...
Page 98
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Lancement d’une session KVM....................41 Gestion d’un équipement à partir de l’interface Web du commutateur AutoView....41 Gestion des comptes locaux...................... 42 Gestion des propriétés des équipements................... 43 Chapitre 5 : Visualiseur vidéo..................
Page 99
All manuals and user guides at all-guides.com Table des Matières Annexes .......................... 67 Annexe A : Mises à jour Flash......................67 Annexe B : Utilisation des modules AVRIQ-SRL................69 Annexe C : Câblage UTP......................... 74 Annexe D : Spécifications techniques ....................76 Annexe E : Émulation des touches avancées du clavier Sun ............
Page 100
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200...
Page 101
All manuals and user guides at all-guides.com LISTE DES FIGURES Figure 1.1 : Exemple de configuration du commutateur AutoView 3100/3200 ........ 3 Figure 2.1 : Configuration de base du commutateur AutoView 3100..........7 Figure 3.1 : Boîte de dialogue Principal de l’interface OSCAR ............. 12 Figure 3.2 : Boîte de dialogue Configuration de l’interface OSCAR ..........
Page 102
All manuals and user guides at all-guides.com viii Guide d’installation et d’utilisation du commutateur AutoView 3100/3200...
Page 103
All manuals and user guides at all-guides.com LISTE DES T ABLEAUX Tableau 3.1 : Fonctions de la boîte de dialogue Principal ............. 12 Tableau 3.2 : Symboles d’état utilisés dans l’interface OSCAR............13 Tableau 3.3 : Concepts de base de la navigation dans OSCAR ............15 Tableau 3.4 : Fonctions de configuration de l’interface OSCAR............
Page 104
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200...
Un accès aux équipements cibles par une voie LAN 1000BaseT. • Un accès aux équipements cibles directement par une voie locale. Le commutateur AutoView 3100/3200 offre un contrôle et une gestion flexibles des équipements cibles depuis n’importe quel endroit dans le monde.
AutoView 3100/3200 n’est pas alimenté. Le module AVRIQ-SRL (série) est un équipement DCE servant d’interface principale entre un équipement série et un commutateur AutoView 3100/3200. Il permet l’émulation de terminal VT100, la suppression des interruptions et l’historique des voies sous un format modulaire compact et pratique.
Chapitre 1 : Présentation du produit Connexion CAT5 Connexion KVM vers le commutateur Connexion IP distante Commutateur AutoView 3200 illustré Ethernet Utilisateur analogique Utilisateur numérique (Interface graphique (Ordinateur équipé ® utilisateur OSCAR d’un navigateur Internet) Figure 1.1 : Exemple de configuration du commutateur AutoView 3100/3200...
Lors de l’utilisation d’une alimentation de secours (alimentation sans coupure), mettez sous tension l’équipement cible, le moniteur puis le commutateur AutoView 3100/3200. NOTA : La meilleure façon de mettre l’équipement hors tension est de le débrancher de la prise de courant.
Installation Connectivité du commutateur AutoView Le système de commutation AutoView 3100/3200 transmet les données du clavier, de la vidéo et de la souris (KVM) entre les opérateurs et les équipements cibles connectés au commutateur AutoView 3100/3200 par l’intermédiaire d’un réseau via une connexion Ethernet.
Page 110
• Mettez l’ensemble sous tension et vérifiez que toutes les connexions fonctionnent. • Configurez le commutateur AutoView 3100/3200 à l’aide de l’interface de menu de la console. • Effectuez les réglages nécessaires au niveau des paramètres de la souris. La Figure 2.1 à la page 7 donne un exemple d’une configuration typique du commutateur...
Utilisateur analogique Réseau Utilisateur numérique Commutateur AutoView 3100 Cordon d’alimentation Voies 1 à 16 Connexions USB locales Serveurs 1 à 16 Modules AVRIQ/IAC, adaptateurs PS/2, USB*, Sun et série disponibles. Figure 2.1 : Configuration de base du commutateur AutoView 3100...
Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Connexion du commutateur AutoView 3100/3200 NOTA : Le commutateur AutoView 3100/3200 peut être monté en rack dans une configuration 1U. Le commutateur AutoView 3100/3200 n’est pas compatible avec une configuration 0U. Connexion et mise sous tension du commutateur AutoView 3100/3200 : 1.
Si aucun des deux voyants ne s’allume, cela signifie que la vitesse de connexion est de 10 Mbits/s. De plus, le panneau avant du commutateur AutoView 3100/3200 est doté de voyants pour chaque voie, indiquant l’état de l’équipement cible concerné : •...
Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Configuration de l’interface Web Vous pouvez accéder au commutateur AutoView 3100/3200 par les périphériques locaux ou par une interface Web intégrée. Avant d’accéder au commutateur via l’interface Web, veuillez spécifier une adresse IP à l’aide de la voie SETUP située sur le panneau arrière du commutateur.
Fonctionnement de la voie locale Contrôle du système par la voie locale Le commutateur AutoView 3100/3200 est équipé d’une voie locale à l’arrière. Cette voie vous permet de relier un clavier, un moniteur et une souris au commutateur pour un accès direct. Le commutateur AutoView 3100/3200 fonctionne avec OSCAR, une interface graphique utilisateur intuitive qui vous permet de configurer votre système et de sélectionner les équipements cibles.
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Figure 3.1 : Boîte de dialogue Principal de l’interface OSCAR Tableau 3.1 : Fonctions de la boîte de dialogue Principal Bouton Fonction Quitter Déconnecte les sessions KVM et utilisateur.
(cercle jaune) Le module AVRIQ désigné est en cours de mise à jour. En présence de ce symbole, ne mettez pas le commutateur AutoView 3100/3200 ou les équipements cibles reliés sous tension puis hors tension et ne déconnectez pas les modules AVRIQ. Cela pourrait entraîner le dysfonctionnement permanent du module et nécessiter le retour à...
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Sélection de l’équipement cible précédent : Appuyez sur , puis sur . Cette combinaison de touches permet de Impr écran Retour arrière basculer entre la connexion actuelle et la connexion précédente.
All manuals and user guides at all-guides.com Chapitre 3 : Fonctionnement de la voie locale Navigation dans l’interface OSCAR Le tableau suivant décrit comment utiliser le clavier et la souris pour naviguer dans l’interface OSCAR. Tableau 3.3 : Concepts de base de la navigation dans OSCAR Touche Fonction Impr écran...
Retour arrière Efface les caractères d’une zone de texte. Fonctions de configuration de l’interface OSCAR Vous pouvez configurer votre système de commutation AutoView 3100/3200 à partir de la boîte de dialogue Configuration de l’interface OSCAR. Sélectionnez le bouton Noms lors de la configuration initiale du système de commutation afin d’identifier les équipements cibles à...
All manuals and user guides at all-guides.com Chapitre 3 : Fonctionnement de la voie locale Accès à la boîte de dialogue Configuration de l’interface OSCAR : 1. Appuyez sur pour lancer l’interface OSCAR. La boîte de dialogue Principal s’affiche. Impr écran 2.
Figure 3.3 : Boîte de dialogue Noms de l’interface OSCAR NOTA : La liste affichée à l’écran est automatiquement mise à jour lorsque le commutateur AutoView 3100/3200 découvre de nouveaux modules AVRIQ. Le curseur de la souris prend la forme d’un sablier pendant l’actualisation de la liste.
All manuals and user guides at all-guides.com Chapitre 3 : Fonctionnement de la voie locale Figure 3.4 : Boite de dialogue Modifier nom de l’interface OSCAR 2. Saisissez un nom dans le champ Nouveau nom. Les noms des équipements cibles peuvent contenir tout caractère imprimable.
Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Figure 3.5 : Boîte de dialogue Équipements de l’interface OSCAR Lorsque le commutateur AutoView 3100/3200 détecte un commutateur en cascade, le format de numérotation change : du format voie AutoView seule, il passe au format [voie AutoView]-[voie du commutateur] afin de prendre en compte tous les équipements cibles reliés à...
All manuals and user guides at all-guides.com Chapitre 3 : Fonctionnement de la voie locale Assignation d’un type d’équipement : 1. Dans la boîte de dialogue Équipements, sélectionnez le nombre de voies voulu. 2. Cliquez sur le bouton Modif. pour ouvrir la boîte de dialogue Modif. équip. Figure 3.6 : Boîte de dialogue Modif.
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Figure 3.7 : Boîte de dialogue Menu de l’interface OSCAR Détermination de l’ordre d’affichage des équipements cibles : 1. Sélectionnez Nom pour afficher les équipements cibles dans l’ordre alphabétique (par nom).
All manuals and user guides at all-guides.com Chapitre 3 : Fonctionnement de la voie locale Contrôle de l’indicateur d’état L’indicateur d’état s’affiche sur le bureau et indique le nom ou le numéro d’EID de l’équipement cible sélectionné ou l’état de la voie sélectionnée. La boîte de dialogue Indicateur permet de configurer l’indicateur de manière à...
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Affichage de l’indicateur d’état : 1. Sélectionnez Nom ou EID pour déterminer l’information à afficher. 2. Sélectionnez Affiché pour que l’indicateur soit toujours affiché ou Temporisé pour que l’affichage ne dure que cinq secondes après une commutation.
All manuals and user guides at all-guides.com Chapitre 3 : Fonctionnement de la voie locale Accès à la boîte de dialogue Diffusion de l’interface OSCAR : 1. Si l’interface OSCAR n’est pas affichée, appuyez sur pour ouvrir la boîte de Impr écran dialogue Principal.
À partir de la boîte de dialogue Commandes, décochez la case Activer la diffusion. Utilisation du mode Balayage En mode de balayage, le commutateur AutoView 3100/3200 examine automatiquement les différentes voies une à une (équipement cible par équipement cible). Vous pouvez spécifier jusqu’à...
All manuals and user guides at all-guides.com Chapitre 3 : Fonctionnement de la voie locale 3. Déterminez l’endroit de la liste où vous souhaitez ajouter l’équipement cible. Si la liste de balayage ne contient aucun équipement cible, le curseur s’affiche sur une ligne vierge en haut de la liste.
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 2. Cliquez sur le bouton Commandes pour ouvrir la boîte de dialogue Commandes, comme indiqué à la Figure 3.12. Figure 3.12 : Boîte de dialogue Commandes de l’interface OSCAR 3.
All manuals and user guides at all-guides.com Chapitre 3 : Fonctionnement de la voie locale Accès à la boîte de dialogue Écon. d’écran de l’interface OSCAR : 1. Si l’interface OSCAR n’est pas affichée, appuyez sur pour ouvrir la boîte de Impr écran dialogue Principal.
La boîte de dialogue Clavier vous permet d’envoyer un paramètre régional d’entrée différent du paramètre américain par défaut. Le paramètre régional d’entrée spécifié est envoyé à tous les équipement cibles reliés au commutateur AutoView 3100/3200 lorsqu’ils sont mis sous tension ou redémarrés et le nouveau code est enregistré dans le module AVRIQ.
Gestion des tâches des serveurs à l’aide de l’interface OSCAR Vous pouvez gérer votre système de commutation AutoView 3100/3200 et les connexions utilisateur, activer les modes de balayage et de diffusion, et mettre à jour le firmware depuis la boîte de dialogue Commandes de l’interface OSCAR.
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Accès à la boîte de dialogue Commandes de l’interface OSCAR : 1. Si l’interface OSCAR n’est pas affichée, appuyez sur pour ouvrir la boîte de Impr écran...
All manuals and user guides at all-guides.com Chapitre 3 : Fonctionnement de la voie locale Figure 3.16 : Boîte de dialogue État utilisateur de l’interface OSCAR Déconnexion d’un utilisateur 1. Si l’interface OSCAR n’est pas affichée, appuyez sur pour ouvrir la boîte de Impr écran dialogue Principal.
La commande de réinitialisation envoie une séquence de connexion à chaud à l’équipement cible, ce qui entraîne l’envoi au commutateur AutoView 3100/3200 des paramètres de la souris et du clavier. Puisque la communication est rétablie entre l’équipement et le commutateur AutoView 3100/3200, l’utilisateur bénéficie à...
All manuals and user guides at all-guides.com Chapitre 3 : Fonctionnement de la voie locale 2. Cliquez sur Commandes - Affichage versions pour ouvrir la boîte de dialogue Version, comme indiqué à la Figure 3.18 à la page 35. La moitié supérieure de la boîte de dialogue donne les versions des sous-systèmes.
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 4. Sélectionnez le module AVRIQ que vous souhaitez visualiser et cliquez sur le bouton Version. La boîte de dialogue Version AVRIQ s’affiche. La Figure 3.20 à la page 36 donne un exemple de cette boîte de dialogue.
Un visualiseur vidéo permet de contrôler en temps réel les fonctions du clavier, du moniteur et de la souris des équipements cibles reliés au commutateur AutoView 3100/3200. Vous avez également la possibilité d’utiliser des macros prédéfinies pour réaliser des actions dans la fenêtre du visualiseur.
À propos de la fenêtre de l’explorateur du commutateur AutoView La fenêtre de l’explorateur du commutateur AutoView d’Avocent s’affiche après la connexion et l’authentification d’un utilisateur. C’est à partir de cette fenêtre que vous pouvez visualiser le commutateur AutoView, y accéder et le gérer. Elle permet également de définir les paramètres système et de modifier les paramètres de profil.
Barre d’options supérieure : met en signet une fenêtre de l’interface Web de l’AutoView, actualise l’affichage de la fenêtre, imprime une page Web, quitte une session logicielle ou accède à la page d’aide de l’assistance technique d’Avocent. Le nom de l’utilisateur connecté apparaît dans la partie gauche de la barre d’options supérieure.
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Utilisation de la barre d’options supérieure Mise en signet d’une fenêtre (avec Internet Explorer uniquement) La barre d’options supérieure de la fenêtre de l’explorateur du commutateur AutoView comporte une icône de mise en signet appelée BOOKMARK (signet).
L’option de mise à jour Flash de l’IQ permet de mettre à jour les modules AVRIQ à l’aide des derniers firmwares disponibles d’Avocent. Cette mise à jour peut être effectuée à partir de l’interface Web du commutateur AutoView ou de l’interface OSCAR.
Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Une fois la mémoire Flash mise à jour, le commutateur AutoView 3100/3200 redémarre à chaud, ce qui interrompt toutes les sessions des modules AVRIQ. Un équipement cible dont le firmware de module AVRIQ est en cours de mise à...
Affichage et modification des paramètres de configuration du matériel La plupart des propriétés des équipements sont accessibles par le navigateur Web du commutateur AutoView 3100/3200. NOTA : Les utilisateurs peuvent visualiser toutes les informations concernant le matériel mais seul l’administrateur peut modifier les paramètres.
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Tableau 4.2 : Affichage des informations relatives au matériel Fonction Sélection Afficher le nom ou le type de l’unité Appliance - Overview (Matériel - Vue d’ensemble) Afficher la liste des équipements cibles disponibles,...
All manuals and user guides at all-guides.com CHAPITRE Visualiseur vidéo À propos de la fenêtre du visualiseur vidéo Le visualiseur vidéo permet de mener une session de commutation KVM sur les équipements cibles reliés au commutateur AutoView. Lors de la connexion à un équipement à l’aide du visualiseur vidéo, le bureau de l’équipement cible s’affiche dans une nouvelle fenêtre, laquelle contient le curseur local et le curseur de l’équipement cible.
(tels que Best color [Jeu de couleurs optimal]). Par conséquent, la modification des paramètres de couleur peut améliorer les performances vidéo. Pour des performances vidéo optimales sur une connexion réseau lente, Avocent recommande les paramètres Grayscale/ Best Compression (Nuances de gris/Compression optimale) ou Low Color/High Compression (Couleurs faibles/ Compression forte).
All manuals and user guides at all-guides.com Chapitre 5 : Visualiseur vidéo Caractéristiques de la fenêtre du visualiseur vidéo La Figure 5.1 présente les zones de la fenêtre du visualiseur vidéo et le Tableau 5.1 à la page 48 les décrit. Figure 5.1 : Fenêtre du visualiseur vidéo (mode d’affichage normal)
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Tableau 5.1 : Description de la fenêtre du visualiseur vidéo Lettre Description Barre de titre : affiche le nom du serveur en cours de visualisation. En mode plein écran, la barre de titre disparaît et le nom du serveur s’affiche entre la barre de menus et la barre d’outils.
All manuals and user guides at all-guides.com Chapitre 5 : Visualiseur vidéo Modification de la barre d’outils Vous pouvez choisir le délai au bout duquel la barre d’outils est masquée lorsqu’elle se trouve dans l’état affichée/masquée (c’est-à-dire, non verrouillée à l’aide de la punaise). Définition d’une durée de masquage de la barre d’outils : 1.
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Réglage de l’affichage Les menus et les boutons de la barre des tâches de la fenêtre du visualiseur permettent de réaliser les tâches suivantes : •...
All manuals and user guides at all-guides.com Chapitre 5 : Visualiseur vidéo Activation et désactivation du mode plein écran : 1. Pour activer le mode plein écran, cliquez sur le bouton Agrandir. -ou- Sélectionnez View - Full Screen (Affichage - Plein écran) dans la barre de menus du visualiseur vidéo.
Cependant, vous pouvez, sur recommandation d’un membre de l’équipe d’assistance technique d’Avocent, régler plus précisément la vidéo à l’aide de la commande Tools – Manual Video Adjust (Outils – Réglage vidéo manuel) de la barre de menus du visualiseur ou en cliquant sur le bouton Manual Video Adjust (Réglage vidéo manuel).
All manuals and user guides at all-guides.com Chapitre 5 : Visualiseur vidéo Figure 5.2 : Boîte de dialogue Manual Video Adjust (Réglage vidéo manuel) Tableau 5.2 : Description de la boîte de dialogue Manual Video Adjust (Réglage vidéo manuel) Lettre Description Lettre Description...
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Largeur de la capture d’image, échantillon de pixels/réglage fin, position horizontale de la capture d’image et position verticale de la capture d’image Les commandes de réglage Image Capture Width (Largeur de la capture d’image), Pixel Sampling/ Fine Adjust (Échantillon de pixels/réglage fin), Image Capture Horizontal Position (Position...
All manuals and user guides at all-guides.com Chapitre 5 : Visualiseur vidéo Réglage vidéo automatique NOTA : Vous avez également la possibilité de régler automatiquement les paramètres vidéo en sélectionnant Tools - Automatic Video Adjust (Outils - Réglage vidéo automatique) dans la barre de menus du visualiseur ou en cliquant sur l’icône Automatic Video Adjust (Réglage vidéo automatique) de la barre d’outils.
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Curseur distant Curseur local Figure 5.3 : Curseurs local et distant affichés dans la fenêtre du visualiseur vidéo Le mode curseur actif dans le visualiseur s’affiche dans la barre de titre, accompagné du raccourci clavier permettant de quitter le mode curseur simple.
All manuals and user guides at all-guides.com Chapitre 5 : Visualiseur vidéo Lorsque le mode curseur unique est activé, utilisez le raccourci clavier défini pour revenir au mode de bureau normal. Quitter le mode curseur unique : Appuyez sur la touche indiquée dans la barre de titre. Modification du paramètre de curseur : 1.
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Mise à l’échelle personnalisée : Cliquez sur le bouton radio Custom (Personnalisé) pour activer les champs X et Y. b. Saisissez une valeur de mise à l’échelle de la souris dans les champs X et Y. Pour toute entrée de la souris, les mouvements sont multipliés par les facteurs de mise à...
All manuals and user guides at all-guides.com Chapitre 5 : Visualiseur vidéo Activation de la transmission des frappes au clavier : 1. Sélectionnez Tools - Session Options (Outils - Options de session) dans la barre de menus du visualiseur vidéo. -ou- Cliquez sur le bouton Session Options.
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Capture d’une image de la fenêtre du visualiseur vidéo dans le presse-papier : Sélectionnez File - Capture to Clipboard (Fichier - Capturer l’image dans le presse-papier) dans la barre de menus du visualiseur vidéo.
Configuration du réseau Configuration des paramètres du réseau à l’aide du menu de la console : 1. Lorsque vous mettez le commutateur AutoView 3100/3200 sous tension, il s’initialise pendant une minute environ. Une fois l’initialisation terminée, appuyez sur une touche quelconque du terminal ou de l’ordinateur exécutant le logiciel d’émulation de terminal pour accéder à...
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Figure 6.1 : Menu principal de la console 2. Dans le menu principal de la console, saisissez et appuyez sur pour accéder à l’option Entrée...
Si vous utilisez l’option DHPC, configurez votre serveur DHPC de sorte qu’il fournisse une adresse IP au commutateur AutoView 3100/3200 et ignorez l’étape 5. 5. Terminez la configuration de votre commutateur AutoView 3100/3200 ; pour ce faire, sélectionnez les options restantes dans le menu Network Configuration et attribuez-lui une adresse IP, un masque de réseau, une passerelle par défaut et une réponse ping.
(Quitter). Tous ces éléments sont présentés dans la section suivante. Security configuration (Configuration de la sécurité) Le commutateur AutoView 3100/3200 est doté d’une base de données interne qui peut être utilisée par le logiciel Remote Operations du commutateur AutoView, la voie locale, ou la voie SETUP si le logiciel DSView Server n’est pas disponible.
All manuals and user guides at all-guides.com Chapitre 6 : Utilisation de la voie terminal Modification du nom d’un utilisateur dans la base de données du commutateur AutoView 3100/3200 : 1. Dans le menu principal de la console, saisissez et appuyez sur pour accéder au menu...
Ce menu permet de rétablir les paramètres par défaut de toutes les options du commutateur. Reset appliance (Réinitialisation du commutateur) Ce menu permet d’exécuter un redémarrage à chaud du commutateur AutoView 3100/3200. Exit (Quitter) Cette option vous ramène au message signalant que le système est prêt. Lorsque le mot de passe de l’interface du menu de la console est activé, vous devez quitter le menu principal de la console de...
TFTP (Trivial File Transfer Protocol). Une fois la mémoire Flash mise à jour, le commutateur AutoView 3100/3200 redémarre à chaud, ce qui interrompt toutes les sessions des modules AVRIQ. Un équipement cible dont le firmware de module AVRIQ est en cours de mise à...
Page 172
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 10. Le commutateur AutoView 3100/3200 lance la procédure de mise à jour Flash. Des indicateurs s’affichent à l’écran pour permettre de suivre le déroulement de l’opération. Lorsque la mise à...
Le module AVRIQ-SRL est un convertisseur série/VGA permettant aux équipements VT100 d’être visualisés par le biais de la voie locale du commutateur AutoView 3100/3200 ou de l’interface Web intégrée. Les données série proprement dites ne sont pas disponibles mais uniquement visibles.
Page 174
Mode AutoView/CD : contrôle le mode de fonctionnement des lignes de détection de la porteuse et du commutateur AutoView 3100/3200. Les options disponibles sont les suivantes : Always on (Toujours activé) et Toggle (Basculer). En mode Toggle, les lignes de détection de la porteuse et l’AutoView sont désactivés pendant une demi-seconde puis activés chaque fois...
All manuals and user guides at all-guides.com ANNEXES • Help Key Sequence (Raccourci clavier de l’écran d’aide) : permet de définir la combinaison de touches affichant le système d’aide en ligne. La combinaison de touches par défaut est Ctrl-F1 • History Key Sequence (Raccourci du mode historique) : permet de définir la combinaison de touches activant le mode History (Historique).
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Utilisation du mode History (Historique) Le mode History (Historique) vous permet d’examiner le tampon de l’historique, qui contient les événements survenus. Le module AVRIQ-SRL dispose d’un tampon de sortie de 240 lignes au minimum (équivalant à...
Page 177
All manuals and user guides at all-guides.com ANNEXES Tableau B.1 : Brochage du module AVRIQ-SRL Broche Nom et description du signal hôte Circulation du signal Nom et description du signal SRL DB9-F DCD - Détection de porteuse Hors du SRL DTR - Terminal de données prêt RXD - Réception de données Hors du SRL...
EIA/TIA 568A et B. Ces normes s’appliquent aux installations faisant appel aux spécifications de câblage CAT 5, 5E et 6. Le système de commutation AutoView 3100/3200 est compatible avec ces deux normes de câblage. Le Tableau C.1 décrit ces normes de câblage.
All manuals and user guides at all-guides.com ANNEXES Installation, maintenance et conseils de sécurité relatifs au câblage La liste suivante détaille des points de sécurité importants à prendre en compte avant toute installation ou maintenance de câbles : • Veillez à ne pas utiliser des câbles CAT 5 de plus de 10 m de long. •...
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Annexe D : Spécifications techniques Le Tableau D.1 dresse la liste des spécifications technique du commutateur AutoView 3100/3200. Tableau D.1 : Spécifications produit du commutateur AutoView 3100/3200 Voies serveur...
Page 181
All manuals and user guides at all-guides.com ANNEXES Tableau D.1 : Spécifications produit du commutateur AutoView 3100/3200 Source d’alimentation Puissance d’alimentation 40 W maximum en courant alternatif Tension d’alimentation en 100 à 240 VCA courant alternatif Courant nominal 0,5 A d’alimentation (c.a.)
All manuals and user guides at all-guides.com Guide d’installation et d’utilisation du commutateur AutoView 3100/3200 Annexe E : Émulation des touches avancées du clavier Sun Il est possible d’émuler certaines touches d’un clavier Sun (US) de type 5 standard en utilisant des combinaisons de touches sur un clavier PS/2.
équipements cibles utilisant des modules Sun AVRIQ-VSN et AVRIQ- WSN et des équipements cibles utilisant les modules AVRIQ-USB. Ces touches fonctionnent normalement si vos serveurs Sun sont reliés au matériel AutoView 3100/3200 via un module AVRIQ-VSN ou AVRIQ-WSN.
Notre équipe d’assistance technique se tient à votre disposition en cas de problème d’installation ou de fonctionnement susceptible de se produire avec un produit Avocent. Si vous rencontrez une difficulté, suivez les procédures ci-dessous afin de bénéficier d’une aide le plus rapidement possible.
Page 185
For Technical Support: www.avocent.com/support Avocent International Ltd. Avocent Corporation 4991 Corporate Drive Avocent House, Shannon Free Zone Shannon, County Clare, Ireland Huntsville, Alabama 35805-6201 USA Tel: +353 61 715 292 Tel: +1 256 430 4000 Fax: +1 256 430 4031...