Page 2
INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. DANGEROUS VOLTAGE This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Page 3
AutoView 2000 Installer/User Guide Avocent, the Avocent logo, The Power of Being There, AutoView and OSCAR are registered trademarks of Avocent Corporation or its affiliates. All other marks are the property of their respective owners. 2004 Avocent Corporation. All rights reserved.
Page 4
USA Notification Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Installing the AutoView 2000 Switch ....................6 Cascading AutoView 2000 Switches....................8 Adding Legacy Switches ........................10 Setting Up Your AutoView 2000 Switching System ................. 11 Chapter 3: Basic Operations..................13 Controlling Your System at the Analog Ports.................. 13 Viewing and Selecting Ports and Servers ..................13 Navigating the OSCAR Interface .....................
Page 9
LIST OF TA BLES List of Tables Table 2.1: Legacy Switch Support ....................10 Table 3.1: OSCAR Interface Status Symbols ................... 14 Table 3.2: OSCAR Interface Navigation Basics ................15 Table 3.3: Setup Features to Manage Routine Tasks for Your Servers.......... 17 Table 3.4: OSCAR Interface Status Flags ..................
KVM switch conveniently supports all major server platforms and features powerful on-screen management for easy system configuration and server selection. A unique benefit of the AutoView 2000 switch is the AVRIQ intelligent module. The AVRIQ module with CAT 5 design dramatically reduces cable clutter, while providing optimal resolution and video settings.
Page 12
Operation modes The OSCAR user interface provides convenient operation modes for easy system administration of the AutoView 2000 switch. These modes (Broadcast, Scan, Switch and Share) allow you to manage your switching activities. Chapter 3 explains these modes in detail.
To avoid potentially fatal shock hazard and possible damage to equipment, please observe the following precautions: • Do not use a 2-wire extension cord in any Avocent product configuration. • Test AC outlets at the computer and monitor for proper polarity and grounding.
Page 14
AutoView 2000 Installer/User Guide Rack mount safety considerations • Elevated Ambient Temperature: If installed in a closed rack assembly, the operation temperature of the rack environment may be greater than room ambient. Use care not to exceed the rated maximum ambient temperature of the unit.
Installation Getting Started Before installing your AutoView 2000 switch, refer to the following list to ensure you have all items that shipped with the appliance as well as other items necessary for proper installation. Supplied with the AutoView 2000 switch •...
Plug the supplied power cord into the back of the appliance and then into an appropriate power source. Figure 2.2 illustrates one possible configuration for your AutoView 2000 switch. See the following detailed set of procedures to successfully install your appliance.
Configuration Port (for updating firmware) AutoView 2000 Switch Servers 2-16 Analog User A AVRIQ Module Server 1 Figure 2.2: Basic AutoView 2000 Switch Configuration To connect an AVRIQ module to each server: Locate the AVRIQ modules for your AutoView 2000 switch.
Bundle and label the cables for easy identification. Cascading AutoView 2000 Switches You can cascade multiple AutoView 2000 switches to enable one or two users to connect to up to 256 servers. In a cascaded system, each ARI (Avocent Rack Interface) port on the main AutoView 2000 switch will connect to the ACI (Avocent Console Interface) port on each cascaded AutoView 2000 switch.
NOTE: The system will automatically “merge” the two switches together as one. All servers connected to the cascaded AutoView 2000 switch will display on the main AutoView 2000 server list in the OSCAR interface. Repeat steps 3 and 4 for all additional (secondary) cascaded AutoView 2000 switches you wish to attach.
AutoView 2000 Installer/User Guide Adding Legacy Switches You can add legacy switches to the AutoView 2000 system for easy integration into your existing configuration. In a cascaded system, each ARI port will accommodate up to 24 servers. See the following table for legacy switches compatible with the AutoView 2000 switch system.
Locate the port set labeled A on the back of the appliance. Connect these peripherals to their respective ports. For the multiuser, 16-port AutoView 2000 switch, repeat steps 1 and 2 for the local analog port set labeled B. Bundle and label the cables for easy identification.
Controlling Your System at the Analog Ports The AutoView 2000 switch features two analog port sets on the back of the unit that allow you to connect a monitor and a PS/2 keyboard and mouse for direct analog access. The AutoView 2000 switch uses the OSCAR interface, which uses intuitive menus to configure your system and select computers.
AutoView 2000 Installer/User Guide NOTE: You can also press the Control key twice within one second to launch the OSCAR interface. You can use this key sequence in any place you see Print Screen throughout this installer/user guide. Viewing the status of your switch The status of the servers in your system is indicated in the right columns of the Main dialog box.
Chapter 3: Basic Operations To select the previous server: Press and then . This key combination toggles you between the previous Print Screen Backspace and current connections. To disconnect the user from a server: Press and then . This leaves the user in a free state, with no server selected. The Print Screen Alt+0 status flag on your desktop displays Free.
Page 26
AutoView 2000 Installer/User Guide Table 3.2: OSCAR Interface Navigation Basics (Continued) This Keystroke Does This Closes the current dialog box without saving changes and returns to the previous Escape one. In the Main dialog box, it closes the OSCAR interface and returns to the flag. In a message box, it closes the pop-up box and returns to the current dialog box.
Chapter 3: Basic Operations Configuring OSCAR Interface Menus You can configure your AutoView 2000 switch from the Setup menu within the OSCAR interface. Select the Names button when initially setting up your appliance to identify servers by unique names. Select the other setup features to manage routine tasks for your servers from the OSCAR interface menu.
AutoView 2000 Installer/User Guide Assigning server names Use the Names dialog box to identify individual servers by name rather than by port number. The Names list is always sorted by port order. Names are stored in the AVRIQ module, so even if you move the cable/server to another ARI port, the name and configuration will be recognized by the switch.
NOTE: If an AVRIQ module has not been assigned a name, the EID is used as the default name. Assigning device types The AutoView 2000 switch automatically discovers cascaded KVM switches, but you will need to specify the number of ports on the cascaded switch through the Devices dialog box. You will see an Sw-8 or Sw-24 display in the Type category for the cascaded switch.
AutoView 2000 Installer/User Guide Figure 3.5: Devices Dialog Box When the AutoView switch discovers a cascaded switch, you will notice the port numbering change to accommodate each server under that switch. For example, if the switch is connected to ARI port 6, the switch port would be listed as 06 and each server under it would be numbered sequentially 06-01, 06-02 and so on.
Chapter 3: Basic Operations Changing the display behavior Use the Menu dialog box to change the display order of servers and set a Screen Delay Time for the OSCAR interface. The display order setting alters how servers will display in several screens including the Main, Devices and Broadcast dialog boxes.
AutoView 2000 Installer/User Guide Controlling the status flag The status flag displays on your desktop and shows the name or EID number of the selected server or the status of the selected port. Use the Flag dialog box to configure the flag to display by server name or EID number, or to change the flag color, opacity, display time and location on the desktop.
Chapter 3: Basic Operations In Display Mode, select Opaque for a solid color flag or select Transparent to see the desktop through the flag. To position the status flag on the desktop: Click Set Position to gain access to the Set Position Flag screen. Left-click on the title bar and drag to the desired location.
Click OK to change only your password, and then close the dialog box. NOTE: If you should lose or forget your password, please contact Avocent Technical Support about returning your switch for service. See Appendix C:Technical Support for contact information.
Page 35
Chapter 3: Basic Operations The Password dialog box displays. Type your password, then click OK. The Main dialog box displays if the password was entered properly. To remove password protection from your console: From the Main dialog box, click Setup - Security; the Password dialog box displays. Type your password, then click OK.
Print Screen Pause Displaying Version Information The OSCAR interface enables you to display the versions of the AutoView 2000 switch and the AVRIQ module firmware. For optimum performance, keep your firmware current. For more information, see Appendix A. To display version information: Press .
Chapter 3: Basic Operations Figure 3.12: AVRIQ Selection Dialog Box Select an AVRIQ module to view and click the Version button. The AVRIQ Version dialog box displays. For more information on loading firmware, see Appendix A. Figure 3.13: AVRIQ Version Dialog Box Click X to close the AVRIQ Version dialog box.
AutoView 2000 Installer/User Guide To add servers to the scan list: If the OSCAR interface is not open, press . The Main dialog box will appear. Print Screen Click Setup - Scan. The Scan dialog box displays. Figure 3.14: Scan Dialog Box The dialog box contains a listing of all servers attached to your appliance.
Chapter 3: Basic Operations Figure 3.15: Commands Dialog Box Select Scan Enable in the Commands dialog box. Click X to close the Commands dialog box. NOTE: Scanning will begin when the Main dialog box or flag is displayed. Scanning is inhibited in any other OSCAR interface dialog box.
AutoView 2000 Installer/User Guide Figure 3.16: Diagnostics Dialog Box Next to each item to be tested, you will see a pass (green circle) or fail (red x) symbol display to the left of each item as that test finishes. The following table details each of the tests.
Chapter 3: Basic Operations Figure 3.17: Diagnostics Warning Dialog Box Click OK to begin diagnostics. -or- Click X or press to exit the dialog box without running a diagnostic test. Escape All users are disconnected and the Diagnostics dialog box displays. As each test is finished, a pass (green circle) or fail (red x) symbol displays.
AutoView 2000 Installer/User Guide Figure 3.18: Broadcast Dialog Box NOTE: Broadcasting Keystrokes - The keyboard state must be identical for all servers receiving a broadcast to interpret keystrokes identically. Specifically, the Caps Lock and Num Lock modes must be the same on all keyboards.
From the Commands dialog box, clear the Broadcast Enable checkbox. Changing Your Switch Mode Your AutoView 2000 switch allows you to connect to attached servers using two methods: Preemptive and Cooperative. Select Preemptive (default setting) to allow any user to select any server at any time; a request from another user disconnects the current user without warning.
AutoView 2000 Installer/User Guide Figure 3.20: Switch Dialog Box Select either Preemptive or Cooperative as your switch mode.
Page 45
Appendix A: FLASH Upgrades Upgrading the AutoView 2000 switch You can upgrade the firmware of your AutoView 2000 switch by using a special update utility provided by Avocent. This utility automatically configures the port communications settings to allow direct downloading from the connected server.
AutoView 2000 Installer/User Guide • In the selected COM port Advanced Port settings, verify that the FIFO buffers are selected and that the receive buffer is set to High. CAUTION: While upgrading, do not use your computer for anything else or switch between windows. Close all other windows if necessary.
AutoView 2000 Installer/User Guide Figure A.4: AVRIQ Selection Dialog Box Select an AVRIQ module to upgrade and click the Version button. The AVRIQ Version dialog box displays. Figure A.5: AVRIQ Version Dialog Box Click the Load Firmware button. The AVRIQ Load dialog box displays.
Appendices Figure A.6: AVRIQ Load Dialog Box Click OK to initiate the upgrade and return to the Status dialog box. NOTE: During an upgrade, the AVRIQ status indicator in the Main dialog box will be yellow. The AVRIQ module is unavailable while an upgrade is in progress. When an upgrade is initiated, any current connection to the server via the AVRIQ module will be terminated.
AutoView 2000 Installer/User Guide Appendix B: Technical Specifications Table B.1: Product Specifications AutoView 2000 Switch Product Specifications Server Ports Number Types PS/2, Sun, USB and serial AVRIQ modules Connectors RJ-45 Sync Types Separate horizontal and vertical Plug and Play DDC2B...
Page 51
Appendices Table B.1: Product Specifications (Continued) AutoView 2000 Switch Product Specifications AC-input 100 to 240 VAC Autosensing voltage rating AC-input current 0.5 A rating AC-input cable 18 AWG three-wire cable, with a three-lead IEC-320 receptacle on the power supply end and a country or region dependent plug on the power resource end...
Page 52
Appendix C: Technical Support Our Technical Support staff is ready to assist you with any installation or operating issues you encounter with your Avocent product. If an issue should develop, follow the steps below for the fastest possible service. To resolve an issue: Check the pertinent section of this manual to see if the issue can be resolved by following the procedures outlined.
Page 53
I N D E X Index adding legacy switches DDC Plug and Play ARI port Device Modify dialog box AutoView 2000 switch Devices dialog box adding legacy switches Diagnostics Warning message 1, 8 cascading features 1, 2 Electronic ID (EID)
Page 54
AutoView 2000 Installer/User Guide Set Position flag setting password password protecting setting Screen Delay Time Setup dialog box soft switching rack mounting status flag rack mounting safety SVGA video removing password protection Switch dialog box switch mode safety precautions changing...
Page 57
AutoView 2000 Guide d’installation et d’utilisation Avocent, le logo Avocent, The Power of Being There, AutoView et OSCAR sont des marques déposées d’Avocent Corporation ou de ses filiales. Toutes les autres marques sont la propriété exclusive de leurs détenteurs respectifs.
Page 58
Notification pour les États-Unis Avertissement : Les modifications apportées à ce produit sans l’accord exprès de la partie responsable de la conformité peuvent annuler l’autorisation dont vous bénéficiez pour utiliser cet équipement. Nota : L’équipement a été testé et déclaré conforme aux limites définies pour les appareils numériques de classe A, suivant l’article 15 du règlement de la FCC.
Page 59
Le module intelligent AVRIQ ......................1 Mesures de sécurité ..........................3 Chapitre 2: Installation ....................5 Démarrage ............................5 Éléments livrés avec le commutateur AutoView 2000 ..............5 Montage en rack du commutateur AutoView 2000 ................5 Installation du commutateur AutoView 2000..................6 Configuration en cascade de commutateurs AutoView 2000.............8 Ajout de commutateurs classiques ....................10...
Page 60
AutoView 2000 Guide d’installation et d’utilisation Annexes .......................... 35 Annexe A : Mises à jour FLASH ......................35 Annexe B : Spécifications techniques....................40 Annexe C : Assistance technique......................42 Index..........................43...
Page 61
Figure 1.2 : Exemple de configuration du commutateur AutoView 2000..........3 Figure 2.1 : Installation horizontale du commutateur AutoView 2000 ..........6 Figure 2.2 : Configuration de base du commutateur AutoView 2000 ..........7 Figure 2.3 : Configuration du commutateur AutoView 2000 avec un commutateur en cascade........................9...
Page 62
AutoView 2000 Guide d’installation et d’utilisation Figure A.1 : Boîte de dialogue AVRIQ Status (État de l’AVRIQ) ..........36 Figure A.2 : Boîte de dialogue AVRIQ Upgrade (Mise à jour de l’AVRIQ) ........37 Figure A.3 : Boîte de dialogue Version ..................37 Figure A.4 : Boîte de dialogue AVRIQ Selection (Sélection AVRIQ)..........38...
L ISTE DES TABLEAUX Liste des tableaux Tableau 2.1 : Compatibilité avec les commutateurs classiques...........10 Tableau 3.1 : Symboles d’état utilisés dans l’interface OSCAR ..........14 Tableau 3.2 : Concepts de base de la navigation dans OSCAR ..........15 Tableau 3.3 : Fonctions de configuration pour gérer les tâches de routine des serveurs...17 Tableau 3.4 : Indicateurs d’état de l’interface OSCAR ...............22 Tableau 3.5 : Détails des tests de diagnostic ................30 Tableau B.1 : Spécifications Produit ...................40...
Page 64
AutoView 2000 Guide d’installation et d’utilisation...
à l’écran facilitant la configuration du système et la sélection des serveurs. L’un des avantages spécifiques au commutateur AutoView 2000 est le module intelligent AVRIQ. Le module AVRIQ de conception CAT5 réduit de façon significative l’encombrement dû aux câbles tout en optimisant la résolution et les réglages vidéo.
Page 66
3 mètres environ et 800 x 600 avec un câble de 15 mètres. Elle varie en fonction de la longueur de câble séparant le commutateur et les serveurs. Plug and Play Le commutateur AutoView 2000 est également conforme au standard d’affichage « Plug and Play » VESA DDC2B qui automatise la configuration de l’écran. Mise à jour FLASH Vous pouvez mettre à...
• Utilisez uniquement des câbles fournis par Avocent pour connecter les ordinateurs aux commutateurs KVM. La garantie d’Avocent ne s’applique pas en cas de dommages liés à l’utilisation de câbles autres que ceux fournis par Avocent. Afin d’éviter tout risque de choc mortel et tout dommage matériel, prenez les précautions suivantes : •...
Page 68
Guide d’installation et d’utilisation du commutateur AutoView 2000 Sécurité relative au montage en rack • Température ambiante élevée : Si l’équipement se trouve en rack fermé, il se peut que la température de fonctionnement du rack soit supérieure à la température ambiante de la pièce.
Un module AVRIQ et un câble UTP par serveur ou commutateur relié Montage en rack du commutateur AutoView 2000 Vous pouvez monter votre commutateur AutoView 2000 en rack à l’aide des supports du kit de montage. Avant l’installation du commutateur et des autres composants dans le rack (s’ils ne sont pas déjà...
Installation du commutateur AutoView 2000 Branchez le cordon d’alimentation fourni à l’arrière du matériel, puis à une source d’alimentation adaptée. La figure 2.2 illustre une configuration possible du commutateur AutoView 2000. Reportez-vous aux instructions détaillées qui suivent afin d’installer correctement votre matériel.
Commutateur AutoView 2000 Serveurs 2 à 16 Utilisateur analogique A Module AVRIQ Serveur 1 Figure 2.2 : Configuration de base du commutateur AutoView 2000 Connexion d’un module AVRIQ à chaque serveur Repérez les modules AVRIQ du matériel AutoView 2000.
Rassemblez et étiquetez les câbles afin de faciliter leur identification. Configuration en cascade de commutateurs AutoView 2000 Vous pouvez monter en cascade plusieurs commutateurs AutoView 2000 afin de permettre à un ou deux utilisateur(s) de se connecter jusqu’à 256 serveurs. Dans un système en cascade, chaque voie ARI (Avocent Rack Interface) du commutateur AutoView 2000 principal est connectée à...
AutoView 2000 principal. NOTA : Le système reconnaît les deux commutateurs en cascade comme un seul ensemble. Tous les serveurs connectés au commutateur monté AutoView 2000 s’affichent dans la liste de serveurs de l’interface OSCAR du commutateur de consoles principal.
Guide d’installation et d’utilisation du commutateur AutoView 2000 Ajout de commutateurs classiques Vous avez la possibilité de connecter des commutateurs classiques au commutateur AutoView 2000 en vue d’optimiser l’intégration de ce dernier à la configuration existante. Dans un système en cascade, chaque voie ARI peut être utilisée par un maximum de 24 serveurs.
Localisez le groupe de voies marqué A à l’arrière de l’équipement. Connectez les périphériques aux voies correspondantes. Dans le cas du commutateur AutoView 2000 à 16 voies pour utilisateurs multiples, répétez les étapes 1 et 2 pour le groupe de voies analogiques marqué B.
Page 76
Guide d’installation et d’utilisation du commutateur AutoView 2000...
Contrôle du système par les voies analogiques Le commutateur AutoView 2000 est équipé de deux groupes de voies analogiques situés à l’arrière de l’unité qui vous permettent de relier un moniteur ainsi qu’un clavier et une souris PS/2 pour un accès analogique direct.
Guide d’installation et d’utilisation du commutateur AutoView 2000 NOTA : Vous pouvez également lancer l’interface OSCAR en appuyant deux fois de suite dans l’intervalle d’une seconde sur la touche Ctrl. Vous pouvez utiliser cette combinaison à chaque fois que vous voyez Impr. écran mentionné...
Chapitre 3: Opérations de base Sélection du serveur précédent Appuyez sur , puis sur . Ce raccourci clavier permet d’alterner entre la Impr écran Retour arrière connexion actuelle et la connexion précédente. Déconnexion de l’utilisateur d’un serveur Appuyez sur puis sur .
Page 80
Guide d’installation et d’utilisation du commutateur AutoView 2000 Tableau 3.2 : Concepts de base de la navigation dans OSCAR (suite) Touche(s) Action Ferme la boîte de dialogue active sans enregistrer les modifications et ouvre la dernière boîte de dialogue affichée. Dans la boîte de dialogue Main (Principal) : Echap ferme OSCAR et affiche l’indicateur.
Chapitre 3: Opérations de base Fonctions de configuration de l’interface OSCAR Vous pouvez configurer votre commutateur AutoView 2000 à partir de la boîte de dialogue Setup (Configuration) de l’interface OSCAR. Cliquez sur le bouton Names (noms) lors de la configuration initiale du matériel afin d’identifier les serveurs par des noms uniques.
Guide d’installation et d’utilisation du commutateur AutoView 2000 Attribution de noms aux serveurs Utilisez la boîte de dialogue Names (Noms) pour identifier chaque serveur par nom plutôt que par numéro de voie. La liste Names (Noms) est toujours triée par numéro de voie. Les noms sont enregistrés dans le moduleAVRIQ donc, même si vous déplacez le câble ou le serveur vers une...
NOTA : Si aucun nom n’a été attribué à un module AVRIQ, le numéro EID est utilisé comme nom par défaut. Assignation des types d’équipement : Le commutateur AutoView 2000 détecte automatiquement les commutateurs KVM en cascade, vous devez cependant préciser le nombre de voies du commutateur en cascade à l’aide de la boîte de dialogue Devices (Équipements).
Guide d’installation et d’utilisation du commutateur AutoView 2000 Figure 3.5 : Boîte de dialogue Devices (Équipements) Lorsque le commutateur AutoView détecte un commutateur en cascade, vous remarquez que la numérotation des voies est modifiée pour prendre en compte chaque serveur de ce commutateur.
Chapitre 3: Opérations de base Modification de l’affichage Utilisez la boîte de dialogue Menu pour modifier l’ordre d’affichage des serveurs et configurer un retard d’affichage de l’interface OSCAR. La configuration de l’ordre de visualisation affecte l’affichage des serveurs sur plusieurs écrans, notamment les boîtes de dialogue Main (Principal), Devices (Équipements) et Broadcast (Diffusion).
Guide d’installation et d’utilisation du commutateur AutoView 2000 Contrôle de l’indicateur d’état L’indicateur d’état s’affiche sur le bureau et indique le nom ou le numéro EID du serveur sélec- tionné ou l’état de la voie sélectionnée. La boîte de dialogue Flag (Indicateur) permet de configurer l’indicateur de manière qu’il affiche le nom ou le numéro EID du serveur ;...
Chapitre 3: Opérations de base Sélectionnez une couleur dans la zone Display Color (Couleur d’affichage). Dans la zone Display Mode (Mode d’affichage), sélectionnez Opaque pour une couleur pleine ou Transparent pour que le bureau soit visible en transparence. Positionnement de l’indicateur d’état sur le bureau Cliquez sur Set Position (Fixer position) pour afficher l’écran Position Flag (Fixer position).
NOTA : En cas de perte ou d’oubli du mot de passe, le commutateur doit être retourné au fabricant pour réparation. Veuillez contacter le service d’assistance d’Avocent. Reportez-vous à l’ Annexe C : Assistance technique pour obtenir les coordonnées.
Chapitre 3: Opérations de base Connexion à la console Appuyez sur n’importe quelle touche du clavier ou déplacez la souris. La boîte de dialogue Password (Mot de passe) s’affiche. Saisissez votre mot de passe puis cliquez sur OK. La boîte de dialogue Main (Principal) s’affiche si le mot de passe saisi est correct. Suppression de la protection par mot de passe de la console Depuis la boîte de dialogue Main (Principal), cliquez sur Setup (Config.) - Security (Sécurité) ;...
Affichage des informations relatives à la version L’interface OSCAR permet d’afficher les informations relatives aux versions du commutateur AutoView 2000 et du firmware du module AVRIQ. Pour optimiser les performances, pensez à mettre à jour régulièrement votre firmware. Pour plus d’informations, consultez l’Annexe A.
Chapitre 3: Opérations de base Figure 3.12 : Boîte de dialogue AVRIQ Selection (Sélection AVRIQ) Sélectionnez le module AVRIQ que vous souhaitez visualiser et cliquez sur le bouton Version. La boîte de dialogue AVRIQ Version (Version AVRIQ) s’affiche. Pour plus d’informations sur le chargement du firmware, consultez l’Annexe A.
Guide d’installation et d’utilisation du commutateur AutoView 2000 Ajout de serveurs à la liste de balayage Si l’interface OSCAR n’est pas lancée, appuyez sur . La boîte de dialogue Main Impr écran (Principal) s’affiche. Cliquez sur Setup - Scan (Config. - Balayage). La boîte de dialogue Scan (Balayage) s’affiche.
Chapitre 3: Opérations de base Figure 3.15 : Boîte de dialogue Commands (Commandes) Sélectionnez Scan Enable (Activer le balayage) dans la boîte de dialogue Commands (Commandes). Cliquez sur la case de fermeture X pour fermer la boîte de dialogue Commands (Commandes). NOTA : Le balayage commence lorsque l’indicateur ou la boîte de dialogue Main (Principal) s’affiche.
Guide d’installation et d’utilisation du commutateur AutoView 2000 Figure 3.16 : Boîte de dialogue Diagnostics À la fin du test, chaque élément testé est précédé d’un symbole de réussite (cercle vert) ou d’un symbole d’échec (croix rouge). Le tableau ci-dessous décrit chacun des tests réalisés.
Chapitre 3: Opérations de base Figure 3.17 : Boîte de dialogue Diagnostics Warning (Avertissement diagnostics) Cliquez sur OK pour lancer le diagnostic. - ou - Cliquez sur X ou appuyez sur pour quitter la boîte de dialogue sans réaliser de test de Echap diagnostic.
Guide d’installation et d’utilisation du commutateur AutoView 2000 Figure 3.18 : Boîte de dialogue Broadcast (Diffusion) NOTA : Diffusion des frappes au clavier - pour que les serveurs destinataires interprètent les combinaisons de touches de manière identique, l’état du clavier doit être le même pour tous les serveurs. Tout particulièrement, les modes Verr Num et Verr Maj doivent être paramétrés de la même manière sur tous les claviers.
(Activer la diffusion). Modification du mode de commutation Le commutateur AutoView 2000 permet de vous connecter aux serveurs reliés de deux manières différentes : en mode Preemptive (Préemption) ou Cooperative (Coopération). Sélectionnez le mode Preemptive (Préemption) (mode par défaut) pour autoriser la sélection à tout moment de n’importe quel serveur par un utilisateur quelconque ;...
Guide d’installation et d’utilisation du commutateur AutoView 2000 Figure 3.20 : Boîte de dialogue Switch (Commutateur) Sélectionnez au choix le mode Preemptive (Préemption) ou le mode Cooperative (Coopération) comme mode de commutation.
Annexe A : Mises à jour FLASH Mise à jour du commutateur AutoView 2000 Avocent fournit un utilitaire spécifique vous permettant de mettre à jour le firmware du commutateur AutoView 2000. Cet utilitaire configure automatiquement les paramètres de communication du port pour permettre un téléchargement direct depuis le serveur connecté.
Guide d’installation et d’utilisation du commutateur AutoView 2000 • Vérifiez dans les paramètres avancés de la voie COM que les mémoires tampon FIFO sont sélectionnées et que la mémoire tampon est définie sur Haute. ATTENTION : N’utilisez pas l’ordinateur pendant la mise à jour, pas même pour basculer d’une fenêtre à une autre.
Annexes Figure A.2 : Boîte de dialogue AVRIQ Upgrade (Mise à jour de l’AVRIQ) Mise à jour du firmware d’un module AVRIQ particulier Appuyez sur . La boîte de dialogue Main (Principal) s’affiche. Impr écran Cliquez sur Commands (Commandes) - Display Versions (Affichage versions). La boîte de dialogue Version s’affiche.
Guide d’installation et d’utilisation du commutateur AutoView 2000 Figure A.4 : Boîte de dialogue AVRIQ Selection (Sélection AVRIQ) Sélectionnez le module AVRIQ que vous souhaitez mettre à jour et cliquez sur le bouton Version. La boîte de dialogue AVRIQ Version (Version AVRIQ) s’affiche.
Annexes Figure A.6 : Boîte de dialogue AVRIQ Load (Chargement AVRIQ) Cliquez sur OK pour lancer la mise à jour et retourner à la boîte de dialogue Status (État). NOTA : Au cours d’une mise à jour, l’indicateur d’état de l’AVRIQ apparaît en jaune dans la boîte de dialogue Main (Principal).
Guide d’installation et d’utilisation du commutateur AutoView 2000 Annexe B : Spécifications techniques Tableau B.1 : Spécifications Produit Spécifications produit du commutateur AutoView 2000 Voies serveur Nombre Types Modules PS/2, Sun, USB et AVRIQ série Connecteurs RJ-45 Types de synchronisation Horizontale et verticale séparées...
Page 105
Annexes Tableau B.1 : Spécifications Produit (suite) Spécifications produit du commutateur AutoView 2000 Tension nominale 100 à 240 VC.A. auto-détecteur d’alimentation (c.a.) Courant nominal 0,5 A d’alimentation (c.a.) Câble d’alimentation (c.a.) Câble trois fils 18 AWG avec fiche à trois conducteurs IEC-320 à...
Notre équipe d’assistance technique se tient à votre disposition en cas de problème d’installation ou de fonctionnement susceptible de se produire avec un produit Avocent. Si vous rencontrez une difficulté, suivez la procédure ci-après afin de bénéficier d’une aide le plus rapidement possible.
Boîte de dialogue Switch (Commutateur) 2, 13 Interface OSCAR Boîte de dialogue Version Message d’avertissement diagnostics CAT 5 Mesures de sécurité Commutateur AutoView 2000 2, 35 Mise à jour FLASH ajout de commutateurs classiques Mode de commutation chargement du rack modification...
Page 108
AutoView 2000 Guide d’installation et d’utilisation Module AVRIQ Serveurs connexion au serveur ajout à la liste de balayage mise à jour attribution de noms Montage des supports du commutateur configuration en vue d’une commutation logicielle Montage en rack déconnexion diffusion Navigation dans l’interface OSCAR...
Page 109
GARANTIE LIMITÉE Avocent Corporation garantit à l’acheteur initial que ce produit est et sera exempt de défaut de matériau et de fabrication pendant une période de 24 mois à compter de la date d’achat. De plus, tous les produits Avocent sont accompagnés d’une garantie inconditionnelle de satisfaction de trente jours.
Page 110
For Technical Support: Visit www.avocent.com/support Avocent International Ltd. Avocent Corporation Avocent House, Shannon Free Zone 4991 Corporate Drive Shannon, County Clare, Ireland Huntsville, Alabama 35805-6201 USA Tel: +353 61 715 292 Tel: +1 256 430 4000 Fax: +353 61 471 871...