Connecting Cables between Indoor Unit and Outdoor Unit
Outdoor
unit
3
2
1
CAUTION
!
The power cable connected to the outdoor unit should be complied with IEC 60245 or HD 22.4 S4
(This equipment shall be provided with a cable set complying with the national regulation.
1 Phase(Ø)
3 Phase(Ø)
The connecting cable connected to the outdoor unit should be complied with IEC 60245 or
HD 22.4 S4 (This equipment shall be provided with a cable set complying with the national
regulation.)
If the supply cable is damaged, it must be replaced by a special cable or assembly availible
from the manufacturer of its service agent.
Indoor
unit
3
2
1
NORMAL CROSS-SECTIONAL AREA
Model
Phase(Ø)
ATUW18GPLS1
ABUW18GM1S1
ATUW48LMLS1
ATUW54LMLS1
ABUW48LM3S1
ABUW54LM3S1
APUW48LT3S1
NORMAL CROSS-SECTIONAL AREA
Model
Phase(Ø)
ATUW18GPLS1
ABUW18GM1S1
ATUW48LMLS1
ATUW54LMLS1
ABUW48LM3S1
ABUW54LM3S1
APUW48LT3S1
WIRING CONNECTION
Area(Ø)
1
2.5
3
2.5
Area(mm²)
1
0.75
3
1.00
9
When the connection
line between the
indoor unit and out-
dooor unit is over 40
m, connect the
telecommunication
line and power line
separately.